Midea MKG Series Technical & Service Manual page 37

50hz ac fan coil unit 2-pipe wall-mounted
Table of Contents

Advertisement

AC Fan Coil Unit Two-pipe Wall-mounted Series
4) Push the TIMER button and the remote controller will show the last set time for the STOP operation and the signal
"h" will be shown on the display panel. You are now ready to reset the time of the STOP operation.
5) Push the TEMP button (
6) After setting the TIMER there will be a one-half second delay before the remote controller transmits the signals to
the Air Conditioner. Then after approximately another 2 seconds, the set temperature will re-appear on the digital
display.
8 Set the STARTING & STOPPING time
1) Please press the CANCEL button to cancel any former settings.
2) Push the TIMER button and the remote controller will show the last setting time for START operation and the
signal "h" will be shown on the display panel. You are now ready to readjust the TIMER ON to start the operation.
3) Push the TEMP button (
4) Push the TIMER button and the remote controller will show the last set time for STOP operation and the signal "h"
will be shown on the display panel. You are now ready to reset the time of the STOP operation.
5) Push the TEMP button (
6) After setting the TIMER there will be a one-half second delay before the remote controller transmits the signal to
the Air Conditioner. Then, after approximately another 2 seconds ,the set temperature will re-appear on the digital
display.
Notes:
1. Please reset the TIMER after cancelling the former time settings.
2. The setting time is relative time. That is the time set is based on the delay of the current time.
13.2 Wired Controller KJR-29B
The Performance features of wired controller are as follows:
1. Operating mode: cool, heat, dry, fan and auto.
2. Set the mode through buttons.
3. Indoor setting temperature range: 17°C ~30°C.
4. LCD (Liquid Crystal Display).
5. Touch key.
6. Can switch Fahrenheit degree and Centigrade degree.
13.2.1 Wired Controller Specifications
Ambient Temperature Range
or
) to set the time you want to stop the operation.
or
) to set the time you want to start the operation.
or
) to set the time you want to stop the operation.
Operating Mode
Transmitting Icon
Setting
Temperature
Operating I co n
MOD E Button
Left Button
FAN S PEED
Button
Model
Power Supply Voltage
Ambient Humidity Range
Ai r Filter Cleaning
Follow Me Icon
Re miding Icon
Temp. Setting Butto n
Timer/Clock Setting Bu tton
- 36 -
Locking Ic on
Fu nction I con
Timer/Clock
Display Area
Operating F an
Speed
Swing Icon
ON/OFF
Button
Right B utton
Si lent/OK
Button
KJR-29B/BK-E
DC 5.0 V
-5°C~+43°C
RH40%~RH90%