TROUBLESHOOTING (CHECK POINT)

19
The unit does not operate.
The power main switch is
turned off.
The circuit breaker is
activated to cut off the
power supply.
Stoppage of electric
current
ON timer is set.
20

REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
pencil. "00" will be shown on the display. (picture 1)
4. Press
during pushing
"00" will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized. (picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
1
Cooling or Heating is abnormally low.
The filters are blocked with dust.
The temperature has been set improperly.
The windows or doors are opened.
The air inlet or outlet of the outdoor unit
is blocked.
The fan speed is too low.
The operation mode is FAN or DRY.
POWER SELECTION function is set
75% or 50% (This function is
depend on remote controller).
. "B" will show on the display and
2