MANUAL DEFROST OPERATION
21
To defrosting the heat exchanger of the outdoor unit during Heating operation.
Press and hold
: for 5 sec. then remote control display will show
SET
[
] as picture 1 for 2 sec.

OPERATION AND PERFORMANCE

22
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor unit
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating.
This is normal because the cracking sound may be caused by
expansion/contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Heating
–25°C ~ 24°C
Cooling
–15°C ~ 46°C
Dry
–15°C ~ 46°C

TROUBLESHOOTING (CHECK POINT)

23
The unit does not operate.
● The power main switch is
turned off.
● The circuit breaker is
activated to cut off the power
supply.
● Stoppage of electric current
● ON timer is set.
24

REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of
2 air conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
pencil. "00" will be shown on the display. (Picture 1)
4. Press
during pushing
"00" will disappear and the air conditioner will turn OFF.
The Remote Control B is memorized. (Picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
1
Room Temperature
Less than 28°C
21°C ~ 32°C
17°C ~ 32°C
Cooling or Heating is abnormally low.
● The fi lters are blocked with dust.
● The temperature has been set
improperly.
● The windows or doors are opened.
● The air inlet or outlet of the
outdoor unit is blocked.
● The fan speed is too low.
● The operation mode is FAN or DRY
● POWER SELECTION function is
set 75% or 50% (This function is
depend on remote controller).
. "B" will show on the display and