noTe: AC power should be turned off at this stage.
• After selecting the proper location for your Alarm, and wiring
the AC QUICK CONNECT harness as described in the WIRING
INSTRUCTIONS, attach the mounting bracket to the electrical
box. To ensure aesthetic alignment of the alarm with the hall-
way, or wall, the "A" line on the mounting bracket should be
parallel with the hallway when ceiling mounted, or horizontal
when wall mounted (See Figure 9-D).
• Pull the AC QUICK CONNECTOR through the center hole in
the mounting bracket and secure the bracket, making sure
that the mounting screws are positioned in the small ends of
the keyholes before tightening the screws.
• Proceed to Section 10 for Kidde App Instructions.
If you are installing for Wi-Fi functionality, and have not yet
downloaded the Kidde App, do not connect your Wi-Fi unit
to the AC quick connect harness or mounting bracket yet. See
Section 10 for instructions on downloading the Kidde App. If you
are not using the Wi-Fi function, then proceed with the following
three steps.
• Plug the AC QUICK CONNECTOR into the wiring harness
attached to the unit, making sure that the locks on the connector
snap into place. Then push the excess wire back into the electrical
box through the hole in the center of the mounting bracket.
• Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direction. noTe: The alarm will
mount to the bracket in 4 positions (every 90 degrees). noTe: Installing the alarm on the mounting bracket will
automatically activate the battery backup.
• Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power.
noTe: Wi-Fi units will emit a series of LED blinks, tones, and voices as the unit(s) search for a Wi-Fi alarm
network. If you are intending to use Wi-Fi units without the Wi-Fi function, ignore these notifications, and
the Wi-Fi function will turn off in about 15 minutes, or you can push/hold the button until you hear two
beeps (about four seconds), to exit Wi-Fi enrollment mode. You can turn the Wi-Fi function on again at a later
date if desired. See Section 11.3 .
When mounting
in a hallway,
the "A" line should
be parallel with the
A
hallway. When wall
mounting, the "A"
line should be
horizontal.
AC connector
shipped with
product
AC connector
Remove
Figure 9-D
Alignment Marks
("A" Line) on
Mounting
Bracket
Mark and drill
two 3/16" (5mm)
holes for wall
anchors
Existing Kidde
AC Connector
(either connector
can be used for
this model)
Install