Check The Installation Status; 5-1) Function For Failure Diagnosis; Test Mode (Manual Operation / Manual Defrost Function) - Samsung RF18A Series Service Manual

French door refrigerator
Table of Contents

Advertisement

5. CHECK THE INSTALLATION STATUS

5-1) Function for failure diagnosis

5-1-1. Test mode (manual operation / manual defrost function)

• Press the '<' and '>' buttons at the same time for at least 6 seconds. The Control Display will blink with an interval of 0.5
seconds. In that case, you may take your fingers off both buttons and press the '>' button to enter the Engineer Mode.
After entering Engineer Mode, press the '<' or '>' key to make the number '1' blinks. Then, press the 'O' button to enter the
Test Mode.
No.
1
3
6
7
9
• If any key on the front of panel is pressed within 15 seconds after the test mode, it will be operated as below sequence :
Manual Operation1(FF) → Manual Operation2(OF r) → Manual Defrost of fridge compartment (rd) → Manual Defrost of fridge
and freezer compartments (Fd) → Cancellation (normal operation, Display all off) → Manual Operation1(FF)
• If any key on the front of panel is not pressed within 15 seconds after the test mode, the test mode will be canceled and it
will be returned to previous mode.
This document cannot be used without Samsung's authorization.
MAC Address Display Mode (Wi-Fi Only)
[ Mode list selectable in Engineer Mode ]
Engineer Mode
Name
Test Mode
Self-diagnostic Function
Load Condition Display Mode
Option Setting Mode