Carbon filters
Conventional carbon and active carbon filters cannot be cleaned. The capacity
of these filters is limited. You can use such filters for about 3-6 months. Replace a
depleted filter. Find further information on the filter packaging.
5
POSSIBLE CAUSE
The plug of the appliance is not
connected to the socket.
The plug has become loose.
The socket is not supplied with
energy.
The fuse is switched off.
ventilation damper blocked.
motor mounting defective.
motor defective
one-way valve is leaky
connection base chimney-telescopic
chimney is leaky
motor not properly fixed
hood not properly fixed
too much distance hood-hob
too much draught because of open
e.g. lids, oven covers to avoid any risk of burns by hot
objects/surfaces and to avoid fire hazard.
Only use self shielded illuminants to avoid any risk of
burns by hot objects/surfaces or fire hazard and to
protect yourself from UV-radiation.
TROUBLE SHOOTING
MALFUNCTION
The appliance does not work at all.
Light is on but motor does not work.
Abnormal motor-smells.
Smear of oil.
Appliance vibrates.
Insufficient extracting capacity.
MEASURE
Check the corresponding socket by
connecting it with another appliance.
Check the fuse.
The voltage is too low. Compare the
data on the model plate with the data
of your energy supplier.
remove blockage.
replace motor.
replace motor
seal the valve
seal the connection with a suitable
material
fix motor properly
fix hood properly
lower position of hood
close the doors/windows
34