G
F
A
B
J
H
I
C
C
CLEARANCE DIMENSIONS — 36" MODEL
Combustible surface
Any materials of a building structure or decorative structure made of wood, compressed paper,
plant fibres, vinyl/plastic or other materials that are capable of transferring heat or being
ignited and burned. Such material shall be considered combustible even though flame-proofed,
fire-retardant treated or surface-painted, or plastered.
F
CLEARANCE DIMENSIONS
A Minimum clearance from glass surface to:
D
E
B Minimum clearance below top of countertop to top of any
C Minimum clearance from side edges of cutout to nearest
D Maximum distance from right edge of cutout to center
E Minimum clearance below top of countertop to junction box
F Minimum clearance from countertop to overhead cabinet
G Minimum distance between overhead cabinets
H Minimum clearance from rear edge of cutout to nearest
I Minimum clearance from front edge of cutout to front edge
J Maximum depth of overhead cabinetry
*To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space
located above the surface units should be avoided. If cabinet storage is to be provided, the risk can
be reduced by installing a range hood that projects horizontally a minimum of 5" (127mm) beyond the
bottom of the cabinets.
A
unprotected wood or metal cabinet; or
cabinet is protected by not less than ¼"-thick flame-retardant millboard covered with not less than
No. 28 MSG sheet steel, 0.015"-thick stainless steel, 0.024"-thick aluminum, or 0.020"-thick copper.
**Refer to your range hood installation guide for further details on clearances.
***Clearance stated is for proud installation of the cooktop. For flush installations, the height of the
cooktop glass should be added to the clearance.
Unprotected overhead cabinet centered above cooktop*†
z
Protected overhead cabinet centered above cooktop*†
z
Range hood**
z
appliance, companion product or obstruction below cooktop***
combustible surface
of junction box
(not directly above the cooktop)
(centered above cooktop)
combustible surface
Distance from rear edge of cooktop to nearest combustible
surface (not shown)
of counter
 = 30" (762mm) minimum clearance between the top of the cooking surface and the bottom of an
 = 24" (610mm) minimum when bottom of wood or metal
A
CI365PTX
IN
MM
30
762
24
610
25 5/8
650
3
75
1 3/16
30
30
762
9
230
23 1/2
450
35 7/16
900
1 3/8
35
1/2
13
1 3/8
35
13
330
9