Maintenance - Nax Power Products NAX 950V Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 30
START UP
CAUTION! For safety reasons, the device cannot work without pipes installed.
To activate the device:
Make sure that the vacuum cleaner stands firmly on the ground.
Always hold the device.
Make sure the spark plug wire is connected to the spark plug.
Several times (4-8 times) press the manual fuel pump 3 (Fig. (Rys.) 4) to bring fuel to the carburetor (it should be
pumped until fuel appears in the pump). (Fig. (Rys. ) 12)
Move the choke lever 4 (Fig. (Rys.) 4) into the choke position
Switch 2 (Fig. (Rys.) 1) set to "I" position. (Fig. (Rys.) 14)
With one hand, holding the vacuum cleaner so that it is stationary, pull the starter cord handle 6 (Fig. (Rys.) 4)
once without jerking, reseting the starter play, and when you feel resistance, strongly and vigorously pull the rope.
(Fig. (Rys. 15))
Next pull the starter rope until the first cycle of work.
After starting the engine, shift the throttle lever lock 25 (Fig. (Rys.) 2) and press the gas trigger 1 (Fig. (Rys.) 1) to
switch off the choke (suction is automatic) (Fig. 16 and 17)
If the engine does not start, check the troubleshooting table.
An improperly mounted suction pipe of the vacuum cleaner or a badly closed rotor side cover may cause the inability to start
the garden vacuum cleaner.
If the engine does not start, despite several attempts, it may mean that the spark plug is flooded. You should then unscrew
the spark plug, wipe and dry it, and then pull the starter cord several times without jerking (without the spark plug and with
the cylinder upside down), thus drying the cylinder with the crankcase from excess fuel. Repeat the entire startup procedure
After starting, allow the engine to run for 2-3 minutes at idle until it warms up.
To turn off the device, slide the On / Off switch 2 (Fig. (Rys.) 1) to the "O" position. Let the engine idle for 1-2 minutes before
stopping the engine.
The maximum operating time of the vacuum cleaner / blower may not be longer than the working time on one fuel
tank. The break should be twice as long as the work time. Do not leave the device running at idle for more than 5
minutes - risk of engine seizing and loss of warranty coverage.
EMPTYING THE LEAF BAG
As the bag fills up, suction power decreases significantly. The bag must be emptied when it is filled. Turn the device off
before emptying the bag. Then slide the zipper fully apart and empty its contents.

MAINTENANCE

The rules for safe maintenance of the device are described in this manual in the section "Maintenance and storage" in the
chapter "Detailed safety rules for petrol vacuum cleaners".
WARNING!
Before cleaning, inspecting or repairing the device, make sure that the engine is switched off and is not hot. Disconnect the
spark plug to prevent the petrol saw from being switched on accidentally.
AIR FILTER CLEANING
A dirty air filter increases fuel consumption and reduces the efficiency of an internal combustion engine. The air filter should
be cleaned as needed, at least every 10 hours of vacuum cleaner operation or earlier if it is dirty.
To remove the filter cover 9 (Fig. (Rys.) 1) unscrew the screw securing the filter cover.
1. Open cover 9 (Fig. (Rys.) 1).
2. Remove the air filter element (Fig. (Rys.) 7).
.
EN
.
39

Advertisement

Table of Contents
loading

Related Products for Nax Power Products NAX 950V

Table of Contents