CHAPTER 3 SIGNALS AND WIRING

3.1 Standard Connection Examples of Full Closed Control Servo Amplifier Control Signals

(1) When MR-J2S-CLP01 is used
NF
Power supply
Three-phase
200VAC
When connecting an external
regenerative brake option,
always disconnect the link
across P-D.
Command pulse
Clear
Ready
In position
Encoder Z-phase pulse
(Differential line driver)
Encoder A-phase pulse
(Differential line driver)
Encoder B-phase pulse
(Differential line driver)
Encoder Z-phase pulse
(Open collector)
Emergency stop
Servo-on
Alarm reset
Proportion control
Torque limit
Forward rotation stroke end
Reverse rotation stroke end
Do not connect when using
an external power supply.
Trouble
Zero speed
Limiting torque
Analog torque limit
MC
Servo amplifier
L1
L2
L3
L11
L21
C
TE2
D
P
CN1A
COM
9
OPC
11
PP
3
PG
13
NP
2
NG
12
CR
8
SG
10
RD
19
RA1
INP
18
RA2
SG
20
LZ
5
LZR
15
LA
6
LAR
16
LB
7
LBR
17
LG
1
OP
14
P15R
4
SD
Plate
CN1B
EMG
15
SON
RES
14
PC
8
TL
9
LSP
16
LSN
17
SG
10
SG
20
VDD
3
COM
13
ALM
18
RA3
ZSP
19
RA4
TLC
6
RA5
P15R
11
LG
1
TLA
12
SD
Plate
TE1
U
V
W
PE
PE
MR-J2S-CLP01
CN2
CN2
MR-J2HBUS M
Use 1M or less.
CN3
2
RXD
12
TXD
1
LG
11
LG
9
SDP
19
SDN
5
RDP
15
RDN
1
LG
11
LG
10
TRE
4
MO1
3
LG
14
MO2
13
LG
Plate
SD
-9-
Servo motor
U
V SM
W
E
Set to CLOSE
CN1B
Standard
encoder cable
CN1A
External encoder
ABZ phase output
Alarm output
5V input for external
encoder
*Option unit
For the wiring method of the
MR-J2S-CLP01 part, refer to
the attached Installation
RS-232C
SD
RD
GND
GND
RS-422
and
RS-422
RS-232C
RDP
are
RDN
exclusive
SDP
functions.
SDN
GND
GND
Connect in the case
of the last axis.
A
Monitor output 1
Monitor output 2
A
BCN-B32110-011

Advertisement

Table of Contents
loading

Table of Contents