40MBAB: Installation Instructions
Dial Code
Control Scenario
OFF is for 1
SW1-1*
and ON is for 2
SW1-2
1,2
SW1-3
1,2
OFF is for 2
SW1-4*
and ON is for 1
SW2-1
2
SW2-1
1
SW2-2
1
SW2-3
1
SW2-4
1
Rotary
1
Switch S3
SW3-1
2
SW3-2
2
SW3-3
2
SW3-3
1
SW3-4
2
SW4
1,2
S4-1
2
S4-2
2
*NOTE: When DIP SWITCH SW1 is set to default, the system
automatically detects the wiring method according to the
three control scenarios. In the event of an unexpected
failure, DIP SWITCH SW1 can be set according to Table 15.
Control Scenario
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 15 — Dip Switch Definitions
Function
Control Function
Anti-cold blow protection option
Single cooling / heating and cooling
options
Control Function
Compressor Running Compensation
(Demand working with heat pump+
Electric heat)
Temperature differential to activate first
stage auxiliary heat (the GAP of T1
and Ts) Wire controller demand with
heat pump + Electric heat working
together
Electric heat on delay
Electric auxiliary heating delay to start
time
Compressor/Auxiliary heat outdoor
ambient lockout
Set outdoor temperature Limitation (for
auxiliary heating or compressor)
Maximum continuous runtime allowed
before system automatically stages up
capacity to satisfy set point. This adds
1 to 5°F to the user set point in the
calculated control point to increase
capacity and satisfy user set point
Cooling and heating Y/Y2 compressor
speed adjustment.
Compressor Running (demand
working with heat pump+ Electric heat)
Temperature differential to activate
second stage auxiliary heating (the
GAP of T1 and Ts) Wire controller
demand with heat pump+ Electric heat
working together
Fan speed of the COOLING mode
when 24V thermostat is applied for.
Electric heat nominal CFM adjustment
Default ON
DH function selection
Wired Controller S1+S2 (1 + 2 + 3)
24V Tstat, S1+S2 (1 + 2 + 3)
ON
24 V Communication
NO
Cooling
Scenario 1
Compressor slower speed
2F
YES
30 minutes
The compressor will not operate if the
outdoor temperature is lower than the
temperature represented by S3
0 means that the temperature
protection is not turned on, the dial
range is 1 through F, 1 equals -4°F
and it increased up to 46°F
30 minutes
Compressor slower speed
Compressor slower speed
4F
Turbo
Available settings are 000/001/010/
011. Each digit corresponds an
individual switch position. For
example [SW4-1 OFF, SW4-2 ON,
SW4 -3 OFF] = 010. See table 11 for
the corresponding CFM adjustment
[Default] For single stage
supplemental heat, W1 and W2 are
connected
[Default] Dehumidification
control not available
1
2
22
OFF
[Default] Auto Detect or RS485 S1-S2
Communication
[Default] YES
[Default] Cooling & Heating
[Default] Auto Detect or Scenario 2
[Default] Faster Compressor
[Default] 4F
[Default] NO
[Default] 15 minutes
[Default] The heater will not operate if the
outdoor temperature is greater than the
temperature represented by S3
[Default] 90 minutes
[Default] Faster Compressor
[Default] Faster Compressor
[Default] 6F
Off
For dual stage supplemental heat, W1 and
W2 are controlled independently.
Dehumidification feature is enabled
through thermostat