023-064X Technical Manual General Description 023-064X series gas detectors are versatile, self-contained gas sensor monitors, used for automated ventilation control and/or warning systems. They can easily be networked together, with or without a central controller into groups. 1.1 Applications: • Vehicle Emissions •...
023-064X Technical Manual Installation Important. All wiring must conform to local building codes, regulations and laws. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 2.1 Sensor Placement Coverage Guidelines for sensor placement of diffusion type sensors are based on the reasonable delay for gas to get from the source to the sensor.
023-064X Technical Manual Physical installation: This device is frequently used with a Manual Pull Station panel, MTT number 961-0001 Refrigerant type R141b Sensor A Active Sensor Alarm AL1 AL2 AL3 PWR Sensor B reading (option) Note: A dedicated transformer is required for each detector.
023-064X Technical Manual Open a knock-out hole for wiring. Wire the power on 24VAC+ and the common on 24VAC- Wire the Sensor A signal output from AN1 and the signal ground on the G terminal Make sure the jumper above the AN1 terminal is towards down to send 2-10V signal on the AN1 output Place the AN2 jumper towards down to send 2-10V signal on the AN2 output Place the according jumper towards up in the case you need to send 4-20mA signal on the output.
023-064X Technical Manual 3.2 User settings list To view the current settings on the model 023-064X, press right several times. To modify the current setting press up or down . To save, press left and up arrows and at the same time. The appearance of **OK** will confirm successful save.
023-064X Technical Manual Operation The power supplied should be between 17 to 28 vac or between 21 to 30 vdc. If the power is too high or too low the sensor will not work properly. Each time the unit is powered on with proper power, the relay is disabled and the analog outputs stay at 0 during the warm up period.
023-064X Technical Manual MT Alliance installation Log into MT Alliance. You must have technician refrigeration configuration permissions. Enter configuration Mode. Select and zoom in the view where the sensor is located. From the Components box Pick and drop a Sensor Then select Absolute Gas Concentration Type, Local Source, Micro Thermo Manufacturer and the Sensor Model and gas type you are going to monitor (pre-defined sensor model will be available in version MTA 8.5.
Page 11
023-064X Technical Manual Select Alarm Settings tab to set the limit values and the set time inside which the monitoring should run without any alarm. You can use predefined values by clicking on Pick Alarm Settings button. Select the Hardware tab to review the sensor manufacturer and model and where you can select the node and input where this sensor is connected.
023-064X Technical Manual To add a missing Sensor model in the list If the required 023-064X model does not exist on your site, you can create one with the Sensor model form in the Configure menu: Click Add and fill the form using the gas type and range accordingly to the table at section 1.3 Ordering information Electrical point values are constant and should always be 9.45V and 2V respectively.
Need help?
Do you have a question about the 023-064 Series and is the answer not in the manual?
Questions and answers