5.4 ENCODER RESET
After having accessed the test mode as indicated on paragraph 5.1, press the PRE-GROUND button to
perform the ENCODER RESET, i.e. the reset of the value of the maximum height of the infuser:
The PRE-GROUND LED will remain steady ON while the reset is in progress, then it will go OFF when the
reset is completed.
IMPORTANT: To complete the encoder reset procedure, start the appliance normally and perform a manual
rinse with the dedicated button.
The infuser must be clean and smooth in its movements to allow the encoder reset to be validated correctly.

6. STATISTICS READING

The appliance allows the reading of the statistics data to understand exactly how the machine operated along
the time.
To access the STATISTICS function:
-
make sure the appliance is ready to use (i.e. in ready-for-coffee mode);
-
hold the SETTINGS and PRE-GROUND buttons pressed for at least 5 seconds:
The LEDs of the buttons dedicated to read the statistics values will illuminate steadily.