CFE -10H User Manual

Residential ess lithium-ion battery

Advertisement

Quick Links

Residential ESS Lithium-ion Battery
CFE-10H User Manual
Published: 0131, 2023
Version 1.08

Advertisement

Table of Contents
loading

Summary of Contents for CFE CFE-10H

  • Page 1 Residential ESS Lithium-ion Battery CFE-10H User Manual Published: 0131, 2023 Version 1.08...
  • Page 2 About CFE RESS Li-ion Battery CFE-10H can be installed in Parallel or Series, more attention should be paid to the DIP and address selection following with part 5.3.2. About this Manual The Manual is intended for the CFE-10H Residential ESS, the hybrid inverter and any other equipment are not included.
  • Page 3: Table Of Contents

    Contents 1 Safety Instructions ...........................1 1.1 Important Safety Instructions ....................1 1.2 Warnings in this Document ....................1 1.3 Battery handling guide ......................2 1.4 Response to emergency situations .................. 2 1.4.1 Leaking batteries ....................2 1.4.2 Fire ...........................2 1.4.3 Wet battery ......................3 1.4.4 Damaged battery ....................3 1.5 Installers ...........................3 1.6 Scrap battery ..........................
  • Page 4 4.5 Safety instruments ......................10 4.6 Communication cable ......................11 4.7 Storage ........................... 11 5 Battery Installation ..........................11 5.1 Package items ........................11 5.2 Checks before installation ....................12 5.3 Installation of the battery ....................12 5.4 Cable connections ......................17 6 Settings for CAN /485 bus pins ......................18 7 Commissioning ............................
  • Page 5: Safety Instructions

    1 Safety Instructions 1.1 Important Safety Instructions This manual contains important instructions for: CFE-Residential ESS Lithium-ion Battery product This manual must be followed when installing and using this product. The product is designed and tested in accordance with international safety requirements IEC 62619/IEC 62040/UL1973, but as with all electrical and electronic equipment, certain precautions must be observed with regard to product installation and/or operation.
  • Page 6: Battery Handling Guide

    1.3 Battery handling guide Use the battery pack only as directed. 1.4 Response to emergency situations The CFE-Residential ESS Lithium-ion Battery is designed with multiple safety strategies to prevent hazards resulting from failures. However, Cannot guarantee their absolute safety for uncertain situations.
  • Page 7: Wet Battery

    Such cases will be addressed within 48h. 1.5 Installers CFE-Residential ESS Lithium-ion Battery is suggested to be installed by skilled workers or electricians. A skilled worker is defined as a person who has received professional training and qualified electrician or possesses all of the following skills and experience: Knowledge of the functional principles and operation of on-grid energy storage ...
  • Page 8: Scrap Battery

    24/7 and we will register your problems and provide reasonable solutions within 48h. Customer careline +86 400 996 8377 2 Product Introduction 2.1 Technical data Model CFE-10H Total Energy* 10.24 kWh Usable Energy(DC) 8.7 kWh Max. Discharge Power 5 KW...
  • Page 9: Indicator And Ports

    IP Rating IP 20 Protective Class Parallel or Series Support 8 Parallel or Series Relative Humidity (RH) 0~95% (No condensed water) Cooling Type Ambient cooling Case Material Metal Color White Installation Wall Mounting Warranty 5 Years Communication CAN/RS485 Protection Mode Triple Hardware Protection Over-Current/ Over-Voltage/ Short Battery Protection...
  • Page 10: Communication Interface Plat

    Table 2-1 Designations on the battery Item Designation Definition Running Battery normally working without fault Fault Battery is in a warning state, see troubleshooting in Chapter 8 Battery indicator light. 2.3 Communication interface plat DIP switch selection for CAN or RS485 Resistance for communication and DIP switch for parallel/series connection...
  • Page 11: How It Works

    Switch for battery’s address selection SW4 & SW5 Communication for battery or master battery with inverter 2.4 How it works Morning Afternoon Optimized self-consumption will Extra energy will be fed into the grid achieved. ESS is used to store excess when ESS is fully charged and system energy produced by PV system.
  • Page 12: Guidance For Batteries During Shipment

    CFE-Residential ESS Lithium-ion Battery is characterized with: Energy storage unit: This battery is suitable for PV solar system compatibility.  Battery management system (BMS): The battery’s built-in BMS monitor prevents  the battery from running outside its design limitations. Expandability: The battery capacity can be increased by adding another battery of ...
  • Page 13: Installation Process

    The Residential ESS is rated at IP20, so the battery could be installed indoors.   If the ambient temperature exceeds the operating range, battery will protect itself by shutting down. The optimal operating temperature of the battery is 15°C to 30°C.
  • Page 14: Tools

     Bipolar external isolators. When two or more battery systems are connected in parallel, each of them shall have a bipolar isolator NOTICE Make sure that the cross-sectional area of charging cables is 25 to 35 mm2. A breaker between battery and inverter is recommended to install, and its min. current should be over 150A or comply with local regulations.
  • Page 15: Communication Cable

    Insulated glove Safety goggles Safety shoes 4.6 Communication cable If needed, the network cable should be made as shown in that diagram. But the network cable between battery and inverter should be produced following the definition of inverter. If available,a LAN cable tester can be used to check whether the cable is faulty 4.7 Storage If the battery is not to be installed immediately, it should be removed from operation.
  • Page 16: Checks Before Installation

    Battery*1 User Manual 5.2 Checks before installation Check the battery voltage. WARNING If this checking process is executed for any reason after the battery is fully installed, make sure that the inverter is turned off or disconnected from battery while checking the battery.
  • Page 17 If the battery is installed above the floor or on a platform, make sure that the wall or platform is capable of supporting the battery’s weight. 5.3.1.1 Wall mounting NOTICE 1. Use the wall mounting bracket to determine the installation position, the lower edge of the bracket should be at least 300mm from the ground, only one product can be installed on a wall bracket.
  • Page 18 For series connection, please make sure the SW2 DIP switch is selected as this type. WARNING Please make sure the SW2 DIP switch is selected correctly. If the battery is connected in parallel mode, and SW2 DIP8 is selected at ON position, it probably leads to serious faults, even dangerous.
  • Page 19 Master Slave 1 Slave 2 Slave 3 Master Slave 1 Slave 2 Slave 3 Slave 4 Master...
  • Page 20 Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Master Slave 1 Slave 2 Slave 3 Slave 4...
  • Page 21: Cable Connections

    Slave 5 Slave 6 Master Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Slave 6 Slave 7 5.4 Cable connections...
  • Page 22: Settings For Can /485 Bus Pins

    WARNING Before connecting battery with inverter, please make sure the inverter turns off. 5.4.1 Cable connection for Series connection NOTICE The voltage difference of each battery should be less than 100mV. 5.4.2 Cable connection for Parallel connection NOTICE Before two or more batteries are installed in parallel, please check the voltage of each battery and make sure the voltage difference is less than 0.5V.
  • Page 23: Commissioning Battery

    7.1 Commissioning battery If there is only one battery installed, the following steps are used to put it in operation: Press and hold the panel button on the left side of the unit for about 4s, and release the panel button after the indicator lights on. Make sure that the Run light is on.
  • Page 24: Warranty Of Residential Ess

    Warranty of Residential ESS This warranty specified below applies to RESS Lithium-ion Battery to consumers through authorized resellers. The accessories and tool kits provided are not included. In the event of a major failure of your unit, you will be entitled to obtain a replacement unit and your warranty will be transferred to the new unit.
  • Page 25 covered by this warranty: Installation or use with any devices not approved as compatible.  Failure to install or use the battery in the way intended, or as demonstrated in the  installation manual including incorrect-installation of cables and connections. Failure caused by charger or inverter unit.
  • Page 26 Ambient temperature: 25 ± 2℃  80%DoD  Total energy/Usable energy measured under specific conditions from 0.2C CC/CV  at DC side. But, if you suspect our verification, the product must be tested by an EU certified origination or a certified 3rd party testing company. Meanwhile, any 3rd party evaluation service fees shall be at your own expense, unless your claim is proven to be valid, in which case will be responsible for the testing costs.
  • Page 27 7 Out Of Warranty In the event the product is out of warranty, may (in its discretion) provide certain after-sales service to Original Buyer, but all related costs and expenses, such as parts, labour costs and travel expenses, shall be borne by Original Buyer. To request such after-sales service, Original Buyer must provide sufficient information about any defects, to enable authorized service partner to determine whether such defects are capable of being repaired.
  • Page 28: Red Declaration Of Conformity (Doc)

    Product name: Lithium-ion battery Type or model: CFE-10H to which this declaration relates is in conformity with the essential requirements and other relevant requirements of the RED Directive (2014/53/EU). The product is in conformity with the following standards and/or other normative documents: HEALTH &...
  • Page 29 First-class power battery system supplier First-class supplier of energy storage and microgrid CF Energy Co., Ltd. Company Address: Intelligent Manufacturing Base , Xianyang , Shaanxi , PRC . Tel: (+86) 029-38367888 Web: www.cfenergygroup.com E-mail:sales@cfenergygroup.com...

Table of Contents