Problem/Report
Fault Diagnosis: Miscellaneous
Problem/Report
No LED Control Lights
Machine Shakes on
Start-up.
Tripping out Electricity
Supply.
No/Inadequate Water
Dispenses
Possible Cause
Leak in supply inlet pipe
work and/or filter.
Leak from machine
water pipe work fittings.
DC tank overfilling.
Possible Cause
No electricity to Machine.
Check Fuse in IEC Socket.
Control PCB not working (Machine
working normally otherwise).
Compressor Starting.
Level Surface.
Uneven Surface.
Missing Fixings.
Machine in high humidity
environment.
Electrical circuitry faults.
Low incoming Water pressure.
Low/no CO2 Pressure.
Suggested Action
Locate and repair accordingly.
Locate and repair accordingly.
Check pressure and fit pressure
reducing valve if needed.
Check level control sensor and
fill valve function.
Suggested Action
Check power supply and reconnect
as necessary (Also check out other
symptoms as described separately).
Replace if necessary.
Check & replace PCB as necessary.
No action needed. This is quite
normal.
Level up machine using adjustable
feet.
Replace missing fixings.
Discuss possible repositioning with
customer.
Test, identify and address
accordingly. See Electrical Diagrams.
Please contact technical support.
Consider re-plumbing to alternative
supply if possible or providing a
pressure boost system.
Check regulator and/or replace
cylinder.