Follow the manual • Never short-circuit the supply terminal in the battery Information marked with this symbol indicates that the compartment! instructions must be observed. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Page 3
Do not leave the packaging lying around. Children may use it as a dangerous toy. Warning The device is not a toy and does not belong in the hands of children. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Polykat fibreglass • dismantled piping • tapping saddle Tubular steel frame • hydrant The images in these instructions show the device LD6000PTS 50m by way of example. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Page 5
Geka coupling 1 inch external thread Bluetooth LED Spare 9 V battery illuminated = connection established flashing = device in pairing mode not illuminated = no connection established, last active connection is paired Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Page 6
Bluetooth transmitter unit Level indication LED bar graph, 10 levels Protection type IP66 Battery 9 V Bluetooth 2.0 / class 2 / 2.4 GHz / + 1.5 dBm (1.14 mW) Range 10 m Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
• the storage temperature complies with the values specified in the Technical data • Batteries are removed from the device • Always store the disinfectant in an upright position (lid facing up). Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
1. Spray the sensor head (3) with the disinfectant (9) and leave it to act for approx. 5 minutes. 2. Fill the storage container (1) to approx. ¼ with disinfectant. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Page 9
Bluetooth Bluetooth LED on No connection Blue LED on connection is speaker illuminated headphones flashes established quickly No connection Bluetooth LED on speaker flashes slowly Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Page 10
2. Carefully slide the sensor head (3) into the pipe through the connected cable passage (2). 4. Connect the Geka coupling to the cable passage (2). ð Make sure that the storage container with the disinfectant (1) is positioned vertically upwards. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Page 11
1. Gradually push the sensor head (3) into the pipe. ð The more of the Level LEDs (22) light up, the closer the sensor head (3) is to the leakage. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Page 12
1. Press the multifunction button (21) for 3 seconds. 33 kHz ð All Level LEDs (22) light up. ð The transmitter unit switches off as soon as you release the multifunction button (21). 33 kHz Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
The level indicator of the transmitter unit flashes in pairing mode: • An error has occurred in pairing mode. Switch the transmitter unit off and back on. Repeat pairing. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
(cable break). Have the device repaired by separately and disposed of in an environmentally friendly authorised expert staff or by Trotec. manner. Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...
Trotec GmbH Grebbener Straße 7, D-52525 Heinsberg Phone: +49 2452 962-400 E-mail: info@trotec.de Place and date of issue: Heinsberg, 17.02.2023 Joachim Ludwig, Managing Director Acoustic tube probe LD6000PTS 50m / LD6000PTS 80m / LD6000PTS 100m / LD6000PTS 150m...