4.0 Maintenance
The Turbo£ Stripper is virtually maintenance free. The guide shaft castings require
lubrication from time to time. (after approx. 1650 sq. feet). Initially the machine is fully
lubricated and should not require any additional lubrication for the first 5000 square feet.
The grease fittings are located on each side. (See Diagram 1) To Grease the gearbox on
it's right side, remove left wheel and bottom cover. Spin axel/gearbox to expose grease
fitting. (See Diagram 2) Put 2 to 3 pumps to gearbox every 50 to 75 hours. The used
grease will flush dirt out of the machine. Replacement lubrication should be a Lithium
based chassis type lube (i.e. auto grease gun pack).
CAUTION!! Press maximum of 3 times with the grease gun. Never press too
much grease into the machine. Otherwise the mechanism will be blocked.
Diagram 1
Diagram 2
7