6.5.2. Encoder Reset

① Turn the controller power [ON] for 3 minutes, and then turn it [OFF].
② Take off the rear cover of the robot. (Check the batteries/encoder backup
batteries are well conneceted.)
③ Turn the controller power [ON].
④ After connecting the reset connector(CNRST1 6) of the axis to reset with the
plug located in the cover of the rear robot for 5 seconds, pull the reset plug
out. (Reset connectors of the respective axis should be connected for the
reset work only. Besides, there is usually no connection in the reset
connector.
⑤ Cover the rear of the robot.

Table 6-5 Reset connectors corresponding to axes

Axis Name Connectin of Reset connector pin [CNRST1 ↔ RESET CONNECTOR]
S
H
V
R2
B
R1
RST1 ↔ RST(1), P5E ↔ RST(2)
RST2 ↔ RST(1), P5E ↔ RST(2)
RST3 ↔ RST(1), P5E ↔ RST(2)
RST4 ↔ RST(1), P5E ↔ RST(2)
RST5 ↔ RST(1), P5E ↔ RST(2)
RST6 ↔ RST(1), P5E ↔ RST(2)