Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HP Manuals
Measuring Instruments
Q METER 4342A
Operating and service manual
Circuit Diagrams - HP Q METER 4342A Operating And Service Manual
Hide thumbs
1
2
3
4
5
6
7
Table Of Contents
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
page
of
169
Go
/
169
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Appendix
Model
4342A
CHANGE
3
Page A-3,
Table
A-l,
Reference
Designation
Index
Change
AlAlC23*
to HP Part
No. 0160-2236;
C:FXD
CER 1pF 500VDCW.
Page A-4,
Table
A-l,
Reference
Designation
Index
Delete
AlAlLlO.
Change
AlAlRl*
to HP Part
No. 0698-4398;
R:FXD
MET
FLM
8.66kS2
1% 1/8W.
Change
AlAlR3*
to HP Part
No. 0698-0083;
R:FXD
MET
FLM
1.96kn
1% 1/8W.
Change
AlAlR4*
to HP Part
No, 0698-4460;
R:FXD
MET
FLM
649Q 1% 1/8W.
Page A-7,
Figure
A-l,
Oscillator
Ass'y
(Option
001) Al
Change
value
of AlAlC23*
to 1pF.
Delete
AlAlLlO
from
circuit.
Change
value
of AlAlRl*
to 8.66ka.
Change
value
of AlAlR3*
to 1. 96kS2.
Change
value
of AlAlR4*
to 64951.
Page A-5,
Table
A-2,
Reference
Designation
Index
Change
A5C13
to HP Part
No. 0140-0205;
C:FXD
MICA
62pF 50/o, and remove
asterisk
(*)
from
A5C13.
Change
A5C15
to HP Part
No. 0160-2262;
C:FXD
CER
16pF 5%, and remove
asterisk
(*)
from
A5C15.
Change
A5C16
to HP Part
No. 0121-0146;
C:VAR
AIR 1.8-16.7pF.
Page A-9,
Figure
A-2,
Impedance
Converter,
RF Amplifier
and Detector
Ass'y(Option
001) A5
Change
value
of A5C13
to 62pF,
and remove
asterisk
(*) from
A5C13.
Change
value
of A5C15
to 16pF,
and remove
asterisk
(*) from
A5C15.
Change
value
of A5C16
to 1.8-16.
7pF.
CHANGE
4
Page A-5,
Table
A-2,
Reference
Designation
Index
Change
A5C13*
to HP Part
No. 0160-2202;
C:FXD
MICA
75pF
5% 300VDCW.
Change
A5C15*
to HP Part
No. 0140-0190;
C:FXD
MICA
39pF 5% 300VDCW.
Change
A5R33
to HP Part
No. 0698-3433;
R:FXD
MET
FLM
28.7Q
1% 1/8W.
Change
A5R42
to HP Part
No. 0757-0442;
R:FXD
MET
FLM
lOkS2 1% 1/8W.
Page A-9,
Figure
A-2,
Impedance
Converter
& RF Amplifier
and Detector
Ass' y (Option
001) A5
Change
value
of A5C13*
to 75pF.
Change
value
of A5C15*
to 39pF.
Change
value
of A5R33
to 28.7R.
Change
value
of A5R42
to 10kSZ.
CHANGE
5
Page
A-6,
Table
A-2,
Reference
Designation
Index
Change
the part
number
of A5R5 to 0730-0149.
III.
C III C UIT DIAGR AMS
Circuit
diagrams
of Oscillator
Ass'y
(Option
001) Al and
Impedance
Converter,
RF Amplifier
and Detector
Ass'y
(Option
001) A5 are given
in Figure
A-l
and A-2.
For other
assemblies,
see SECTION
VIII CIRCUIT
DIAGRAMS.
A-2
Table of
Contents
Previous
Page
Next
Page
1
...
157
158
159
160
Advertisement
Table of Contents
Troubleshooting
Elementary Troubleshooting Guide
70
Troubleshooting, Oscillator Section
77
Troubleshooting, Voltmeter Section
79
Related Manuals for HP Q METER 4342A
Measuring Instruments HP 4396A Operation Manual
Network/spectrum analyzer (21 pages)
Measuring Instruments HP 4328A Operating And Service Manual
Milliohmmeter (125 pages)
Measuring Instruments HP 438A Operating And Service Manual
Power meter (307 pages)
Measuring Instruments HP 436A Operating And Service Manual
Power meter (104 pages)
Measuring Instruments HP 436A Operating And Service Manual
Power meter (102 pages)
Measuring Instruments HP 432A Manual
Power meter (79 pages)
Measuring Instruments HP 431B Operating And Service Manual
Power meter (8 pages)
Measuring Instruments HP 431B Calibration Procedure
Power meter (18 pages)
Measuring Instruments HP 437B Service Manual
Power meter (57 pages)
Measuring Instruments HP 435B Operating And Service Manual
Power meter (119 pages)
Measuring Instruments HP 400D Operating And Servicing Manual
Vacuum tube voltmeter (50 pages)
Measuring Instruments HP 4155A Quick Start Manual
Parameter analyzer (34 pages)
Measuring Instruments HP 4155A Print/Plot Manual
Semiconductor parameter analyzer (61 pages)
Measuring Instruments HP 400D Organizational, Ds, Gs, And Depot Maintenance Manual
Vacuum tube voltmeter (73 pages)
Measuring Instruments HP 400E Operating And Service Manual
Ac voltmeter (58 pages)
Measuring Instruments HP 428B Operating And Service Manual
(52 pages)
Related Content for HP Q METER 4342A
400E Circuit Diagrams
HP 400E
3580A Troubleshooting And Circuit Diagrams
HP 3580A
428B Circuit Diagrams
HP 428B
5061B Circuit Diagrams
HP 5061B
LOGIC PULSER 546A Integrated Circuit U1
HP LOGIC PULSER 546A
3720A Integrated Circuit Identification
HP 3720A
3048A The Phase Lock Loop Circuit
HP 3048A
3575A Diagrams
HP 3575A
3400A Schematic Diagrams
HP 3400A
200AB Circuit Description
HP 200AB
82324 Handling Circuit Boards And Ics Safely
HP 82324
400D Circuit Description
HP 400D
3455A Circuit Description
HP 3455A
4262A Circuit Mode
HP 4262A
333A Power Supply Circuit
HP 333A
3400A Servicing Etched Circuit Boards
HP 3400A
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL