Mount and connect the Power Supply Connect the Wi-Fi antenna Connect the LAN cable Overview of the electrical installation Configuration Connecting to the Charge Amps Amp Guard Wi-Fi hotspot Wi-Fi configuration Electrical settings Verify Charge Amps Amp Guard configuration Cloud configuartion...
Page 3
Neglecting to follow and carry out the directions, instructions and safety precautions in this Installation Manual implies that any warranty provisions will be cancelled and that Charge Amps AB can reject any and all claims for compensation in connection with any injuries/damage or incidents – direct or indirect –...
• Do not immerse the product in water, subject it to physical abuse or insert foreign objects in any part of the product. • Never attempt to disassemble the product in any way. • Charge Amps Amp Guard is a power monitor. Only use the product for its intended use.
230 VAC (+/- 15%) 50 Hz Power Supply Installation DIN Rail mounting in a cabinet: 1M Charge Amps Amp Guard 1M Power Supply Dimensions (W x D x H) Charge Amps Amp Guard: 17,5 x 73 x 100 mm...
Page 6
English Characteristics of functions according to IEC 61557-12 Function symbols Function Measuring range Other performance class complementary characteristics 0-63 A 85-256 VAC...
English 3 Product overview 3.1 Parts WARNING! Note the marking on the Power Supply.
Page 8
English Monitoring Module Terminal block for Status indicators with current sensors voltage measurement Reset button (top of Charge Amps Amp 12 V power cable Charge Amps logo) Guard 230 VAC Power Wi-Fi antenna Supply Serial number and Power Supply AC...
English 3.2 Package contents • Charge Amps Amp Guard • 230 VAC Power Supply, which powers the Charge Amps Amp Guard • Monitoring Module, consisting of a Sensor Cartridge and three connected Current Sensors including cables • Terminal block for voltage measurement •...
Page 10
No light – Voltage measurement not connected Current measurement status: Green light – Ok Red light – Error, incorrect phase order No light – Current measurement not connected Charge Amps logotype: Lights On – Power On Lights Off – Power Off...
English 3.4 Reset If necessary, it is possible to restart Charge Amps Amp Guard using the reset button. Data stored in Charge Amps Cloud will not be affected. 1. Press gently the reset button, the top of the Charge Amps logo.
English 4.2 Internet access IMPORTANT! Charge Amps Amp Guard must be connected to the internet to supply data to the Load Balancer Function which communicates with the charging station(s). The customer must thus provide an internet connection via a network cable (LAN) or Wi-Fi (802.11b/g/n 2.4 GHz).
Please note that an additional slot will be needed for the Power Supply. 5.2 Connect the current sensors Charge Amps Amp Guard comes with three current sensors, one for each phase. 1. Clamp the current sensor around the incoming phase.
English 2. Connect the sensor cartridge to the top of the Charge Amps Amp Guard. 5.3 Connect voltage measurement For installations with power generating equipment Solar panels, wind power, or plans to introduce such equipment require connection of the voltage measurement.
1. Turn the power off at the main switch. 2. Connect phases and neutral to the included terminal block. 3. Connect the terminal block to the bottom of the Charge Amps Amp Guard. 5.4 Mount and connect the Power Supply The Power Supply provide 12V to the Charge Amps Amp Guard.
5. Turn the power on at the main switch. WARNING! Note the marking on the Power Supply. 5.5 Connect the Wi-Fi antenna 1. Mount the included Wi-Fi antenna to the Charge Amps Amp Guard. 2. Note that depending on the type of cabinet, an external Wi-Fi antenna could be needed.
English 5.6 Connect the LAN cable If applicable, connect the network cable to the LAN port. The cable shall be CAT6-classified. 5.7 Overview of the electrical installation WARNING! Note the marking on the Power Supply. Optional, see chapter Connect voltage measurement.
The serial number can be found on the front label of the Charge Amps Amp Guard (the one with a QR-code). 3. Enter the Charge Amps Amp Guard PIN as Wi-Fi password to sign in to the Wi-Fi hotspot. The PIN is an 8 digit code that can be found on the Charge...
English 4. When connected to the Wi-Fi hotspot, start a web browser and type in 192.168.251.1 as URL. 5. Enter the Charge Amps Amp Guard PIN to sign in. 6. Click Login. 6.2 Wi-Fi configuration Charge Amps Amp Guard need access to the customer/facility network in order to connect to the Charge Amps Cloud Load balancing function, using LAN or Wi-Fi.
English 3. Click Update. Charge Amps Amp Guard will connect to the customer/facility Wi-Fi network. 4. Sign in to the Wi-Fi hotspot again. 5. Make sure the communication status symbol lights up green (within about a minute). 6.3 Electrical settings...
2. Select the Status tab. 3. Check that that the measurements on the Status tab look correct. There is also a System tab where the Charge Amps Amp Guard can be rebooted or restored to factory settings, if needed.
English 6.5 Cloud configuartion Charge Amps Amp Guard need to be configured in Charge Amps Cloud to set up Charge Amps Load balancing function. Sign in to the Charge Amps Cloud Partner Portal and use the Installation Wizard for setup and configuration.
Page 23
English Charge Amps App Please download our App for full control, adjusting settings and enabling smart charging and scheduling. Charge Amps Cloud Partner Portal User Portal https://my.charge.space/ https://my.charge.space/ partner Full product information Product information https://www.chargeamps.com/product/charge-amps-amp-guard/ If any question is not answered in this installation manual, please...