6.

Location

Refer to Fig. 3.1
It is recommended that any soft material flooring is removed
from where the Module will be installed.
Any adjacent walls that project above the height of the hob
must be of heat resistant material.
The side wall above the hob shall be greater than 3" (76mm)
from the cooker.
Surfaces over the top of the cooker must not be closer than
30" (762 mm) and must not exceed 13" (330mm) in depth.
The vent slots in the back of the top plate (or shroud) must
not be obstructed.
If possible, any hot water pipes should be directed away
from the cooker. In the event it is not possible the extension
channel section at the rear of each side plate may be
removed. If required to clear hot water or flue pipes with the
following provisos:-
If hot water pipes pass at the rear, they should be lagged and
a 1 15/16" (50 mm) air gap provided to the left-hand side of the
cooker.
NOTE: It is advisable that the supply cable is routed away
from any hot surfaces i.e. hot water/flue pipes.
In the interest of safety, due consideration must be given to
the protection of the electric cable to the cooker.
If a supply cord is damaged it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The appliance is designed for the voltage stated on the rating
plate, which is situated in the centre vent slot near the base of
the front plate.
Recommended, but not mandatory, to fit an individual
Residual Current Device (RCD) for the cooker supply circuit to
avoid nuisance tripping.
An electrical socket type 14-30R must be provided within
5 feet of the left-hand side of the range and accessible for
disconnection.
DO NOT position socket above or behind the range.
An easily accessible manual shut off gas valve must be fitted
before the metal flexi gas line supply to the range. DO NOT fit
valve behind the range.
Any opening in the wall behind the appliance and in the floor
under the appliance must be sealed.
A minimum clearance of 39 5/16" (1000 mm) must be available
at the front of the cooker to enable it to be serviced.
DO NOT install the cooker behind a decorative door
n
in order to avoid overheating.
10