4-14) When The Unit Keeps Alarming (Buzzer Sound) - Samsung RR39M7 Series Service Manual

Table of Contents

Advertisement

TROUBLESHOOTING

4-14) When the unit keeps alarming (Buzzer Sound)

- 2 BOARD
[Note]
1. Fridge / Freezer Door Open Alarm : It sends out an alarm sound when it passes over 2 minutes after the door is open. And, when the door
remains open, it will keeps alarming every minute.
2. When the door is not closed properly, MICOM recognizes it as Door Open and sends out an alarm sound. When it passes over 10 minutes after
it recognizes the Door Open, the room lamps will be off. At this time, when the Door is completely open, the Lamp will not be on right away,
but after a while.
1) When there is "Ding Dong" sound not stopping
Door & MICOM State
Door
Close
Open
Remove and measure the continuity of
Door S/W by pressing it (On/Off).
Check if the value changes between 0Ω
and ∞Ω.
2) When it keeps 'Beeping'
Water penetrates into
MICOM #8
changes when the Door
0V
5V
Check MAIN PCB and
The unit is not in Forced
again, it keeps beeping?
Check if there is any foreign
substance at Test Jumper of MAIN
PCB or any part shorted out
Start
Door stays open?
Closed
Door S/W?
No
MICOM #8 Voltage
is open/close?
Yes
Connector (CN31) is
inserted properly?
Yes
Door S/W is in good
condition?
Yes
Door S/W
Start
Operation or Forced
Defrost mode.
No
When the unit is
plugged out and in
Yes
85
Gap exists
Check if there is any obstacle
pushing the Door open.
Yes
Replace Door S/W
No
Repair Wire Cut / Door S/W
No
Insert the Connector
No
Replace Door S/W
Yes
Cancel Forced Operation/Defrost
No
MAIN PCB is normal

Advertisement

Table of Contents
loading

Table of Contents