TROUBLESHOOTING
Error Code
No
RZ32R7*
RR39R7*
RQ32R7*
RZ11M7*
9
10
11
12
13
14
15
16
Item
Description
Comp
The error code is
Abnormal
displayed when the
Current
compressor location
Detection Error
detection failed.
The error code is
Comp Motor
displayed when the
Restriction Error
compressor motor is
constrained.
The error code is
Comp Low
displayed when the AC
Voltage Error
input voltage is low.
The error code is
Comp
displayed when the
Overvoltage
AC input voltage is too
Error
high.
When Open/Short
Exterior
error from the exte-
Humidity
rior humidity sensor
Sensor Error
occurs.
WIFI
When the WiFi Module
Communication
and Micom communi-
Error
cation error occurs
The error code is
CompIPM Shut
displayed when a
down Error
compressor IPM Shut
Down error occurs
The error code is dis-
Comp
played when a com-
Communication
pressor and Micom
Error
communication error
occurs
Troubleshooting
Check the compressor wire
connections.
Check the soldering status
of the inverter PCB.
(Check if any parts have
short-circuited).
Check the Comp and Cycle.
Check if the compressor
and the Cycle is normal.
Check the input voltage.
Check the soldering of the
inverter PCB.
(Check if any parts have
short-circuited.)
Check Input voltage. (This
error occurs when the
input voltage is below
voltage or lower.)
AC 53V(Input power AC
110~127V) or
AC 106V(Input power
AC 220~240V)
Check Input voltage. (This
error occurs when the
input voltage is below
voltage or higher.)
AC 155V(Input power
AC 110~127V) or
AC 310V(Input power
AC 220~240V)
Voltage between MAIN
PCB CN 30 #2 AND
#3 should be within
4.5V~1.0V.
Check the connection
between MAIN PCB CN02
and WIFI Module.