Vacuum Pump - Prochem LGTPC Operating Instructions Manual

Mobile cleaning unit
Table of Contents

Advertisement

Maintenance

Vacuum Pump

Refer to the Vacuum Pump Operation and Service
Manual for specific instructions.
Lubrication: We recommend that you use AEON PD-
XD synthetic lubricant. AEON PD-XD synthetic
lubricant is formulated especially for AEON PD-XD
rotary positive displacement blower service to provide
maximum protection for all operation temperatures
NOTE: AEON PD-XD synthetic lubricant is the oil
which PROCHEM puts in the vacuum pump at the
factory. Topping off or adding petroleum oil to
synthetic oil is NOT recommended.
1. Check the oil level daily to assure the proper level.
PROPER LEVEL cannot be overemphasized. Too
little oil will ruin bearings and gears. Too much oil
will cause overheating. Use the illustration as a
guide when adding oil.
2.
To prevent rust from building up inside the vacuum
pump (if moisture exists) we have provided a lubri-
cation cup on the front of the unit.
First run the unit at least 1 minute to remove any
moisture from the vacuum pump. Next, fill the
lubrication cup with water displacing lubricant, for
5 seconds while the unit is running and the vac-
uum inlets are sealed. Do this at the end of each
working day.
44
3. Drain, flush and replace oil every 1500 hours or
yearly, whichever comes first. Change oil more
frequently if inspection so indicates.
Vacuum pump oil capacity is approximately 14 ounces
at gear end.
4. Vacuum pump lubrication is vital to performance of
our pump. Failure to follow the maintenance
schedule in the "Maintenance Schedule" can lead
to permanent damage to your blower.
Refer to the Vacuum Pump Operation and Service
Manual for specific instructions.
5. Bearings on the drive end of the blower require
grease lubrication every 250 hours of operation.
86411060 Manual Operators - Legend GT

Advertisement

Table of Contents
loading

Table of Contents