Vacuum Pump - Prochem EVEREST EFI LP Operating Instructions Manual

Table of Contents

Advertisement

MAINTENANCE

VACUUM PUMP

Refer to the Vacuum Pump Operation and Service
Manual for specific instructions.
Lubrication: We recommend that you use AEON
PD Synthetic Blower Lubricant in the gear end of the
vacuum pump for all operating temperatures. AEON
PD is formulated especially for positive displacement
blower service to provide maximum blower
protection at any temperature. One filling of AEON
PD will last several times longer than a premium
mineral oil.
NOTE: AEON PD (Part# 05-008039) is the oil
which PROCHEM puts in the vacuum pump at
the factory. Topping off or adding petroleum oil
to synthetic oil is NOT recommended.
If not using AEON PD synthetic blower lubricant, use
oils with rust and oxidation inhibitors, anti-foam
additives and the viscosity's listed on the chart on
the next page.
1. Check the oil level daily to assure the proper
level. PROPER LEVEL cannot be
overemphasized. Too little oil will ruin bearings
and gears. Too much oil will cause overheating.
Use the illustration as a guide when adding oil.
4-5
2.
3. Drain, flush and replace oil every 1500 hours or
EVEREST EFI 980197 06/30/04
To prevent rust from building up inside the
vacuum pump (if moisture exists) we have
provided a lubrication cup on the front of the
unit.
First run the unit at least 1 minute to remove
any moisture from the vacuum pump. Next, fill
the lubrication cup with WD-40, or a similar
lubricant, for 5 seconds while the unit is running
and the vacuum inlets are sealed. Do this at the
end of each working day.
yearly, whichever comes first. Change oil
more frequently if inspection so indicates. With
AEON PD synthetic lubricant, perform the oil
change maintenance every 4500 hours or
every 2 years, whichever comes first.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Everest efi hp

Table of Contents