2.1 Operating Instructions
Stop! Read Safety information above.
• Set thermostat to lowest setting.
• Turn "OFF" all electrical power to appliance.
• This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light
burner by hand!
• Lift and remove front door.
• Turn gas control knob clockwise
position. See Figure 2-1
• Wait 5 minutes for any gas to clear. Smell for gas,
including near floor. If you smell gas, STOP! Follow
instructions on this page: "What To Do If You Smell
Gas." If you do not smell gas, go to next step.
• Turn gas control knob counter clockwise
open position.
• Turn "ON" electrical power to appliance.
• Set thermostat to desired setting.
• If the appliance will not operate, follow instructions TO
TURN OFF GAS TO APPLIANCE and call your service
technician or gas supplier.

2.2 To Turn Off Gas To Appliance

• Set thermostat to lowest setting.
• Turn "OFF" all electric power to appliance if service is
to be performed.
• Remove access panel(s).
• Turn gas shutoff control knob clockwise
closed position.
• Replace access panel(s).

LIGHTING INSTRUCTIONS

Figure 1- 1 - Gas Valve
to closed
to
to
5
Gas Control Knob
(Shown in closed
position)
PN 240013741 REV. A [12/01/2022]