Patton electronics 2292 Quick Start Manual page 9

Leased-line extenders over ip
Hide thumbs Also See for 2292:
Table of Contents

Advertisement

2.2 Login
Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to
1.
display. Type the factory default login: administrator and leave the password empty. Press the Enter key
after the password prompt.
login:administrator
password: <Enter>
172.16.40.1>
2.
After you have successfully logged in you are in the operator execution mode, indicated by > as com-
mand line prompt. With the commands enable and configure you enter the configuration mode.
172.16.40.1>enable
172.16.40.1#configure
172.16.40.1(cfg)#
Enter the following commands for the first SmartNode 229x device in the pair:
3.
Copy nvram:a-side-config startup-config
Copy running-config startup-config
Follow the same procedure for the other SmartNode 229x device in the pair:
4.
Copy nvram:b-side-config startup-config
Copy running-config startup-config
The configuration above is only a sample configuration that you may use as an example. You should
Note
specify your own parameters such as your IP address and other related information as required. For
detailed information about configuring and operating your SmartNode, set-up procedures, and trouble-
shooting, refer to the SmartNode Series SmartWare Software Configuration Guide on the CD-ROM that
came with your unit.
Reboot both units and connect them back-to-back through their Ethernet 0/1 ports. Voice connections will
5.
automatically be set up between the units.
The steps above will configure the IP addresses as well as the required configurations for voice connections.