3
Should water be present in the salt compartment?
Yes, it is normal to see water at a level of 50mm above the salt grid
(see page 15). If water is not present to this level:
a:
Fill the salt bay with water until the level is 50mm above the salt grid. Then
conduct a manual regeneration.
b:
To manually regenerate using a Phillips head screwdriver push down on
the actuator, and slowly turn CLOCKWISE ONLY until the actuator tab has
advanced the indicator dot to the word "BRINE".
c:
You will hear a rush of water and air going to the drain.
d:
When the vessel has finished its cycle (approx 11 mins), repeat the procedure,
advance the indicator dot to the word "BRINE" in the next section and allow
to finish (approx 11 mins).