SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE TABLE OF CONTENTS Introduction ............................2 Installation ............................2 Water Test Results ........................2 General Installation and Service Warnings ................... 2 Site Requirements ......................... 2 Installation Drawing ........................3 System Drawing ..........................4 Plumbing Instructions ........................
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE INTRODUCTION The Pre-Treatment Chemical Removal system removes the Chlorine and other volatile chemicals. This manual must be read prior to installation and service of Pre-Treatment Chemical Removal Filter. INSTALLATION Water Test Results Parameter Water Sample Results Hardness...
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE System Drawing Plumbing Instructions BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM...
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE Filter Installation With Soft-Tec System Setup 1) Unpack the system and confirm the components with list. If missing anything report the missing part to dealer immediately. 2) Fasten the bypass valve nuts on the head of the tank. 3) Turn the bypass valve handles to the bypass position by facing both handles outwards.
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE Installation Instructions 1) The water heater’s inlet must be at least 10ft away from filter. 2) The unit must be located in a room temperature above 33° F. 3) If vacuum occurrence is expected then the vacuum breaker must be installed at the inlet of the filter.
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE BYPASS VALVE NORMAL OPERATION The inlet and outlet handles of bypass valve should be pointing towards the direction of flow. Inlet is labelled on tank head as downflow inlet. Water flows downwards through the filter bed. BYPASS OPERATION The inlet and outlet handles point towards the center of bypass valve.
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE START UP INSTRUCTIONS 1. Turn off the cold main water supply and inlet to hot water tank to the home and open inside cold faucets to relieve any pressure within the plumbing system. 2.
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE SERVICE INSTRUCTIONS Media Replacement Step 1: - Shut the inlet water supply off by turning valve clockwise. Step 2: - Open the faucet downstream of the filter to release the pressure and then shut off the faucet. Step 3: - Turn the bypass valve handles towards the center to bypass operation.
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE Optional Sediment Filter Cartridge Replacement (if exists) Step 1: - Shut off the main water supply. Step 2: - Press the red button on the housing to release the pressure. Step 3: - Loosen the blue housing by turning it counter clockwise with service wrench. Step 4: - Remove the old cartridge and insert the new cartridge filter onto the stand pipe.
SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE TROUBLESHOOTING PROCEDURES Problem Possible Cause Solution a. Bypass valve is open or faulty a. Fully close bypass valve or replace b. Test water and adjust pre-treatment b. Water quality fluctuation 1. Unfiltered water is if exists being delivered c.
Warranty ~ Coverage Outlined Excalibur Water Systems guarantees, to the original owner, a period of 5 or 7 years, the IN–OUT HEAD to be free of defects in materials and workmanship and to perform its proper functions. Other parts to be free of defects in materials and workmanship and to perform their normal functions to the original owner, the MINERAL TANK will not rust, corrode, leak, burst or in any other form fail to perform their proper functions for a LIFETIME period of 20 YEARS.