Protection against humidity
If a dry storage space is not available, protect the machine as follows against humidity:
• Wrap the machine in humidity-absorbent material.
• Wrap the machine in plastic film:
– Place a humidity meter inside the plastic film.
– Place desiccant within the plastic film, e.g. BRANOgel.
– Pack the machine air-tight.
• Inspect the machine regularly.
4.15.5

Temperature limits during storage

The materials used are specially designed for the temperature range required by the customer.
The relevant temperature limits are specified on the rating plate.
Risk of explosion due to damaged sealing materials
Storing machines at temperatures that do not fall within the specified limits can damage the
material of the seals and cause them to no longer seal correctly. The certified type of protection
of the machine can no longer be complied with.
As a result, a potentially explosive gaseous atmosphere can enter the machine and be ignited
during commissioning. Explosions can occur. This can result in death, serious injury or material
damage.
4.16

Converter operation

The following chapter is relevant only if the machine is suitable for converter operation. Whether
the motor is only suitable for line operation or also for converter operation - with or without
filter - is stamped on the rating plate.
1MB5 shaft height 400/450
Operating Instructions, 04/2023, A5E52802354A
WARNING
Do not store the machine in conditions that lie outside the specified temperature limits.
Preparing for use
4.16 Converter operation
43