ELECTRICAL SHOCK HAZARD - Do not pressure test above 2.4 Bar. Pressure
testing must be done by a trained pool professional. Circulation equipment that
is not tested properly might fail, which could result in severe injury or property
damage.
When pressure testing the system with water, it is very important to make sure
that the pump basket lid is completely secure.
Fill the system with water, using care to eliminate trapped air.
Pressurize the system with water to no more than 2.4 Bar (241 kPa).
Close the valve to trap pressurized water in the system.
Observe the system for leaks and/or pressure decay.
FIGURE 7 - EXPLODED VIEW OF LID ASSEMBLY
32
Lid with
Locking
Ring
and
Seal
Pump
Debris
Trap
Basket
(Inside
Pump)