Zodiac FloPro e3 Instructions For Installation & Use

Zodiac FloPro e3 Instructions For Installation & Use

Filtration pump

Advertisement

FloPro™ e3
H0538700.C - 2017/01
Instructi ons for installati on and use -
Filtrati on pump
Translati on of the original instructi ons in french
More documents on:
www.zodiac-poolcare.com
English
EN

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac FloPro e3

  • Page 1 FloPro™ e3 Instructi ons for installati on and use - English Filtrati on pump Translati on of the original instructi ons in french More documents on: www.zodiac-poolcare.com H0538700.C - 2017/01...
  • Page 3 • This appliance is compati ble with all types of water treatment used in swimming pools. Refer to the Zodiac® warranty conditi ons for details of the permitt ed water balance values. • Never run the pump dry or out of the water as this will invalidate the warranty.
  • Page 4: Table Of Contents

    • The distributi on or modifi cati on of this document in any way is prohibited, without prior authorisati on from Zodiac®. • Zodiac® is constantly developing its products to improve their quality. The informati on contained herein may therefore be modifi ed without noti ce.
  • Page 5: ❶ Specifi Cati Ons

    ❶ Specifi cati ons 1.1 I Descripti on FloPro™ e3 pump Union connecti on Ø63/50 mm x2 Pump base 1.2 I Technical specifi cati ons Unit FloPro™ e3 Operati ng water temperature 2 to 35°C Nominal voltage of motor 230 Vac-50 Hz Motor power - phases Admissible variati on in motor voltage ±...
  • Page 6: I Dimensions And Marking

    1.3 I Dimensions and marking : Pool water inlet : Pool water outlet : Pre- fi lter cover : User interface : Pump motor : Drain Front Side Weight: 10 Kg 1.4 I Performance curves Manometric head Flow rate...
  • Page 7: ❷ Installati On

    ❷ Installati on 2.1 I Selecti ng the locati on • The pump must be installed: - before the fi lter, a heati ng and/or water treatment system, - at a minimum distance of 3.5 metres from the edge of the pool, to avoid any water being sprayed onto the appliance.
  • Page 8: I Hydraulic Connecti Ons

    2.2 I Hydraulic connecti ons • Respect the directi on of hydraulic connecti on (see § “1.3 I Dimensions and marking”). • Choose the dimension of the pipes according to the size of the pool and respecti ng the hydraulic rules which apply in the country of installati on.
  • Page 9: I Power Connecti Ons

    2.3 I Power connecti ons • Before any work on the appliance, you must disconnect the electricity supply to avoid the risk of electric shock which may cause material damage, serious injury or even death. • Only a qualifi ed and experienced technician is authorised to carry out any service, including cabling work within the appliance or to replace the power cord.
  • Page 10: ❸ Use

    ❸ Use 3.1 I Operati ng principle The fi ltrati on pump forms the core of the pool and is essenti al as it is used to circulate water through the pool’s diff erent components, in parti cular the fi lter. Its motor drives the turbine in rotati on, which drives the water.
  • Page 11: I Additi Onal User Functi Ons

    3.4 I Additi onal user functi ons 3.4.1 Using speeds Speed Keys to start the speed Default speed 1400 rpm "ECO" speed 2150 rpm "CLEAN" speed 2850 rpm "BOOST" speed "PRIMING" speed Automati c at start-up 2850 rpm for 2 minutes •...
  • Page 12: ❹ Maintenance

    ❹ Maintenance 4.1 I Winterising • The pump must be fully wintered in the event of a risk of frost or extended electrical disconnecti on. If the pump freezes it may cause severe damage and invalidate the warranty. • To avoid damaging the appliance with condensati on, do not fully cover it. •...
  • Page 13: ❺ Troubleshooti Ng

    ❺ Troubleshooti ng • If a problem occurs, before you contact your retailer, please carry out these few simple checks using the following tables. • If the problem conti nues, contact your retailer. • : Acti ons to be performed by a qualifi ed technician only 5.1 I Appliance behaviour •...
  • Page 14: I Error Codes

    5.2 I Error codes Number of Malfuncti on Possible causes Soluti ons fl ashes User interface is • The user interface resets • Check the electrical defecti ve itself constantly connecti ons inside the user interface housing. • Replace the motor - interface assembly if necessary.
  • Page 15 Votre revendeur Your retailer Modèle appareil Appliance model Numéro de série Serial number Trouvez plus d’informations et enregistrez votre produit sur More informations and register you product on www.zodiac-poolcare.com ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.

Table of Contents