LP Gas Model only:
Connect Regulator with Hose to your LP Gas Tank
Turn all Burner Valves to the OFF position.
Inspect the valve connection port and regulator
assembly for damage or debris. Remove any debris.
Never use damaged or plugged equipment.
Connect the regulator assembly to the tank valve
and HAND TIGHTEN nut clockwise to a full stop.
DO NOT use a wrench to tighten because it could
damage the Quick Coupling Nut and result in a gas
leak/fire hazard.
Open the tank valve (counterclockwise) 1/4 to 1/2
of a full turn, and use a soapy water solution to
check all connections for leaks before attempting
to light your grill. See "Check all connections for LP
Gas Leaks". If a leak is found, turn the tank valve
off and do not use your grill until the leak is repaired.
CAUTION: When the appliance is not in use, the gas must
be turned off at the tank. Place dust cap on cylinder valve
outlet whenever the cylinder is not in use. Only install the
type of dust cap on the cylinder valve outlet that is provided
with the cylinder valve. Other types of caps or plugs may
result in leakage of propane.
CAUTION
!
If you have a gas leak that cannot be repaired by
tightening, turn off the gas at the source, disconnect
fuel line from your grill and call 1-877-419-2598 ; or
your gas supplier for repair assistance.
CAUTION
!
Do not store spare LP cylinder within
1.
10 feet (3m) of this appliance.
2.
Do not store or use gasoline or other
flammable liquids and vapors within 25
feet (8m) of this appliance.
3.
When cooking with oil/grease, do not
allow the oil/grease to get hotter 350°F
(177°C)
4.
Do not leave oil/grease unattended.
Care & Use Instructions
Type 1 connection per CSA/ANSI
Z21.58-2022 • CSA 1.6-2022
Quick
Coupling Nut
!
!
Check all connections for LP Gas Leaks
Never test for leaks with an open flame. Prior to first
use, at the beginning of each season, or every time
your LP Gas tank is changed, you must check for gas
leaks. Follow these three steps:
Make a soap solution by mixing one part liquid
detergent and one part water.
Turn the grill Control Knobs to the full OFF position,
then turn the gas ON at source.
Apply the soap solution to all gas connections
indicated by the arrows. See diagram. If bubbles
appear in the soap solution the connections are
not properly sealed. Check each fitting and tighten
or repair as necessary.
Gas Valve/
Manifold
Side Burner
Assembly
Connection Hose
LP Gas Tank
Disconnecting A Liquid Propane Gas (LPG)
Tank From Your Grill
Make sure the Burner Valves and LP Gas tank valve
are off. (Turn clockwise to close.)
Detach the hose and regulator assembly from the
LP Gas tank valve by turning the Quick Coupling
Nut counterclockwise. Do not use a wrench or any
tools when turning the Quick Coupling Nut.
!
CAUTION
Failure to read and follow the Use and Care
Instructions could result in a fire or explosion that
could cause serious bodily injury, death or prop-
erty damage.
Regulator with
Hose (LPG)
!
36 |
P a g e

Advertisement

Table of Contents
loading