Redbusbar SS10LNAN Manual

10 year lithium battery power photoelectric smoke alarm with option card
Hide thumbs Also See for SS10LNAN:

Advertisement

Quick Links

Part Number: SS10LNAN
Description:
10 Year Lithium Battery Power Photoelectric Smoke Alarm with Option Card
PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM.
1
Read all Instructions before Installation and Operation
Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good
condition. It is recommended that the smoke alarm be replaced after 10 years of normal service. The only user-
serviceable parts are the Option Card batteries. Refer to 'Replacing the Backup Batteries'.
EQUIPMENT INSTALLATION HAZARD
• This product must only be used for the purpose described in these instructions and must be installed in accordance
with the local regulations.
• Ensure that the product has been correctly installed and tested for safe operation.
• Smoke Test each interlinked alarm. Check to ensure every interlinked alarm, alarms correctly. If any unit fails to
alarm, refer to 'Troubleshooting'
Failure to follow these instructions may result in equipment damage or injury.
Smoke Alarm – Top View
1
Mounting Base – Top View
6
SmokeSight SS10LNAN V0.9.0
SmokeSight Residential Smoke Alarm
1. Option Card
2. Alarm (Red)
2
3. Smoke Alarm
4. Option Card
5. Option Card
6. Locking Tab
7
7. Tamper Clip
7
By Redbusbar
(White) LED
LED
Power Switch
Battery Holder
Enable
Switches
Smoke Alarm – Bottom View
5
4
Mounting Base – Bottom View
7
7
3
6
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SS10LNAN and is the answer not in the manual?

Questions and answers

Summary of Contents for Redbusbar SS10LNAN

  • Page 1 SmokeSight Residential Smoke Alarm By Redbusbar Part Number: SS10LNAN Description: 10 Year Lithium Battery Power Photoelectric Smoke Alarm with Option Card PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM. Read all Instructions before Installation and Operation Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good condition.
  • Page 2: Specifications

    In a residential dwelling, mount the smoke alarm in the centre of the ceiling. In mobile homes, wall mount the smoke alarm on an inside partition to avoid the thermal barrier that may form under the ceiling. SmokeSight SS10LNAN V0.9.0 Page 2...
  • Page 3: Locations To Avoid

    8. If tamper prevention is required, slide the Tamper Clip between the ceiling and the mounting base, locking tab. The Tamper Clip can be removed by gripping it with pliers and pulling the clip away from the smoke alarm. SmokeSight SS10LNAN V0.9.0 Page 3...
  • Page 4 ON and the alarm still doesn’t sound, replace the smoke alarm. If the smoke alarm is installed in a mobile home, test weekly and after every journey. After the Test+Hush button has been pressed, wait 10mins before any additional SmokeSight SS10LNAN V0.9.0 Page 4...
  • Page 5: Option Card

    1. Before powering any smoke alarm, place all smoke alarms and their 2xAA option card batteries on a table. 2. Confirm that the Radio Interlink switch is set to ON for each alarm. Refer to Enable Switches for details. SmokeSight SS10LNAN V0.9.0 Page 5...
  • Page 6 If the smoke alarm is in alarm state or receives an interlink signal from a smoke alarm that is in alarm state, the option card, white LED flashes in high intensity mode. This feature assists evacuation by illuminating the escape path or could be used to better signal an alarm to a hearing impaired resident. SmokeSight SS10LNAN V0.9.0 Page 6...
  • Page 7: Troubleshooting

    2. If it’s chirping, 1 or more beeps every 40secs and the chirps do not coincide with white LED flashes, refer to smoke module troubleshooting below. 3. If it’s chirping, 4 or more beeps every 5mins and the chirps coincide with white LED flashes, refer to option card troubleshooting below. SmokeSight SS10LNAN V0.9.0 Page 7...
  • Page 8 1. Identify which smoke alarm/s are in alarm state – Look for the alarm/s sounding and with red LED fast flashing. 2. On each smoke alarm in alarm state press the Test+Hush button to silence the alarm 3. Disconnect all smoke alarms in the alarm state by removing them from their base. SmokeSight SS10LNAN V0.9.0 Page 8...
  • Page 9 Test+Hush button and confirm smoke alarm sounding. If it fails to sound, replace the smoke alarm. If it sounds but fails subsequent Auto Tests, either disable Auto Test and perform manual tests for the remaining life of the alarm, or replace the smoke alarm. SmokeSight SS10LNAN V0.9.0 Page 9...
  • Page 10: Warranty

    Australia and New Zealand. Warranty Redbusbar Pty Ltd, warrants this product to be free from defects in materials and workmanship for a period of 5 (five) years from the date of installation. Refer to the Redbusbar terms of sale for full warranty conditions http://www.redbusbar.com/Terms-and-Conditions.html...
  • Page 11 This page intentionally left blank SmokeSight SS10LNAN V0.9.0 Page 11...
  • Page 12 This page intentionally left blank SmokeSight SS10LNAN V0.9.0 Page 12...