Redbusbar SS10LNAN Instructions Manual

Smokesight residential smoke alarm
Hide thumbs Also See for SS10LNAN:

Advertisement

Quick Links

Part Number: SS10LNAN
Description:
10 Year Lithium Battery Power Photoelectric Smoke Alarm with Option Card
PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM.
Read all Instructions before Installation and Operation
Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good
condition. It is recommended that the smoke alarm be replaced after 10 years of normal service. The only user-
serviceable parts are the Option Card batteries. Refer to 'Replacing the Backup Batteries'.
EQUIPMENT INSTALLATION HAZARD
• This product must only be used for the purpose described in these instructions and must be installed in accordance
with the local regulations.
• Ensure that the product has been correctly installed and tested for safe operation.
• Smoke Test each interlinked alarm. Check to ensure every interlinked alarm, alarms correctly. If any unit fails to
alarm, refer to 'Troubleshooting'
Failure to follow these instructions may result in equipment damage or injury.
Smoke Alarm – Top View
1
Mounting Base – Top View
6
SmokeSight SS10LNAN V0.5
SmokeSight Residential Smoke Alarm
1. Option Card
2. Alarm (Red)
2
3. Smoke Alarm
4. Option Card
5. Option Card
6. Locking Tab
7
7. Tamper Clip
7
By Redbusbar
(White) LED
LED
Power Switch
Battery Holder
Configuration
Switches
Smoke Alarm – Bottom View
5
4
Mounting Base – Bottom View
7
7
3
6
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SS10LNAN and is the answer not in the manual?

Questions and answers

Summary of Contents for Redbusbar SS10LNAN

  • Page 1 SmokeSight Residential Smoke Alarm By Redbusbar Part Number: SS10LNAN Description: 10 Year Lithium Battery Power Photoelectric Smoke Alarm with Option Card PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM. Read all Instructions before Installation and Operation Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good condition.
  • Page 2: Specifications

    In a residential dwelling, mount the smoke alarm in the centre of the ceiling. In mobile homes, wall mount the smoke alarm on an inside partition to avoid the thermal barrier that may form under the ceiling. SmokeSight SS10LNAN V0.5 Page 2...
  • Page 3: Locations To Avoid

    The Tamper Clip can be removed by gripping it with pliers and pulling the clip away from the smoke alarm. Installation is not complete until the red and white LEDs are functioning correctly and the alarm has been checked for correct operation. SmokeSight SS10LNAN V0.5 Page 3...
  • Page 4: Option Card

    Auto Test Configuration Built (3 flash, 3 beep) (4 flash, 4 beep) Node 1 Tap 4 Tap Count Add Radio Node / Build Radio Network (5 flash, 5 beep) Detailed information regarding the mode options follows: SmokeSight SS10LNAN V0.5 Page 4...
  • Page 5 Weekly Frequency – Following 1 long flash beep, Tap 1,2,3 Days from Today – Following 1 long flash beep, Tap 1 to 7 Hours from Now – Following 1 long flash beep, Tap 1 to 24 Return to Operation Mode SmokeSight SS10LNAN V0.5 Page 5...
  • Page 6: Troubleshooting

    Failure of any node will not prevent alarm transmission as the network is self-healing. Initial Setup 1. Switch on/Confirm that the Radio Interlink switch is set to ON. Refer to Configuration Switches for details. SmokeSight SS10LNAN V0.5 Page 6...
  • Page 7 5flash + 5beep every 10secs and select ‘Add Radio Node / Build Radio Network Mode’. From ‘Operation Mode’ this can be achieved by 4Tap, 1Tap, 1Tap of the Test+Hush button within 2mins of the SmokeSight SS10LNAN V0.5 Page 7...
  • Page 8 4Tap of the Test+Hush button. On any network alarm confirm that the built node count reported in ‘Operation Mode’ agrees with your expected node count. Delete Radio Network This function deletes an existing radio interlink network. SmokeSight SS10LNAN V0.5 Page 8...
  • Page 9 Test+Hush button on that alarm. An alarm in alarm state is evidenced by its red LED flashing rapidly. As clap volume and timing may vary, you may need to repeat clap silence more than once. The alarm must incorporate an option card for clap silence to function. SmokeSight SS10LNAN V0.5 Page 9...
  • Page 10: Smoke Alarm

    After the Test+Hush button has been pressed, wait 10mins before any additional testing is conducted to avoid any false alarm responses as the alarm is in reduced sensitivity mode during this period. Refer to ‘Hush‘. SmokeSight SS10LNAN V0.5 Page 10...
  • Page 11 Red LED flashes every The smoke alarm is functioning Normal operating condition. 5mins. correctly. Red LED flashes every 8 to The smoke alarm is in low Wait 10mins to return to normal operating 12secs. sensitivity mode. Test+Hush mode. SmokeSight SS10LNAN V0.5 Page 11...
  • Page 12: Warranty

    Australia and New Zealand. Warranty Redbusbar Pty Ltd, warrants this product to be free from defects in materials and workmanship for a period of 5 (five) years from the date of installation. Refer to the Redbusbar terms of sale for full warranty conditions http://www.redbusbar.com/Terms-and-Conditions.html...

This manual is also suitable for:

Smokesight ss10lnan

Table of Contents