IMPORTANCE OF PM SCHEDULE EXECUTION
Battery Electrolyte Level & Specific Gravity Checking
Pulsar 150/180 DTS-i
Service Station Manual
1. Open the side cover panel.
2. Clean the battery & battery terminal.
3. Inspect battery for damage / leakage.
4. Open all the 6 caps.
5. Check specific gravity by using hydrometer in all six cells one by one.
63
Dealer Development Center