Chapter 4 Configuration| CME-DN01
Attribute
Access
ID
Rule
49
Get/Set
50
Get/Set
51
Get/Set
52
Get/Set
53
Get/Set
54
Get/Set
55
Get/Set
56
Get/Set
Common services
Service Code
0X05
0x0E
0x10
Explanation: User can set following variables for DataConf object by the requirement.
1.
dlen_in/dlen_out: for user to select input/output length when communicating with
DeviceNet network. Maximum length of dlen_in/dlen_out is 16 bytes.
NOTE
After changing these two settings, the settings of Rx size and Tx size of I/O Parameters in
scanner module is needed to be same as these two settings. Or there will be fault and cannot
connect to DeviceNet network when running CME-DN01.
4-2
Name
Data Type
Data_in[1]
UINT
Data_in[2]
UINT
Data_in[3]
UINT
Data_in[4]
UINT
Data_in[5]
UINT
Data_in[6]
UINT
Data_in[7]
UINT
Data_in[8]
UINT
Implemented for
Class
Yes
Yes
No
Description
word input data
st
1
word input data
nd
2
word input data
rd
3
word input data
th
4
word input data
th
5
word input data
th
6
word input data
th
7
word input data
th
8
Class
Yes
Yes
Yes