Advertisement

Quick Links

DeviceNet (CME-DN01)
User Manual
DeviceNet is a trademark of the Open DeviceNet Vendor Association, Inc.
The information supplied by this document is subject to change without notice. No
responsibility or liability for the correctness of the information supplied within this
document is assumed.

Advertisement

Table of Contents
loading

Summary of Contents for Delta DeviceNet CME-DN01

  • Page 1 DeviceNet (CME-DN01) User Manual DeviceNet is a trademark of the Open DeviceNet Vendor Association, Inc. The information supplied by this document is subject to change without notice. No responsibility or liability for the correctness of the information supplied within this document is assumed.
  • Page 2: Table Of Contents

    Table of Contents Chapter 1 Preface ..................1-1 1.1 Receiving and Inspection..............1-1 1.2 Using this Manual ................1-1 1.3 Features....................1-2 Chapter 2 Overview ..................2-1 2.1 Outline ....................2-1 2.2 Description..................2-1 2.3 Network Example................2-2 2.4 The Distance of Trunk Line..............2-2 2.5 The Length of Drop Cable..............2-2 2.6 Installation...................2-3 Chapter 3 Quick Start ..................3-1 3.1 Setting Steps for Installation ...............3-1...
  • Page 3 Appendix A Installation Information ............A-1 A.1 Dimension ..................A-1 A.2 Ambient Conditions ................A-1 A.3 Product Certifications .................A-2 Appendix B DeviceNet Object ..............B-1 Appendix C Auto EDS Generator Software..........C-1...
  • Page 5: Chapter 1 Preface

    Chapter 1 Preface 1.1 Receiving and Inspection All Delta CME-DN01 have gone through rigorous quality control tests at factory prior to ship. After receiving CME-DN01, please check that the package includes: 1pcs CME-DN01, 1pcs communication cable (RJ-45, 8 pins), 1 instruction sheet.
  • Page 6: Features

    Chapter 1 Preface| CME-DN01 1.3 Features The communications adapter device acts as a gateway from DeviceNet network to MODBUS network. Install on the AC drives directly. Defined as a DeviceNet Communications Device Profile 12 (0xC). There are 8 I/O addresses used to control the length by setting. The I/O mapping address can be set by the DeviceNet manage software system, such as RSNetWorx®...
  • Page 7: Chapter 2 Overview

    Chapter 2 Overview 2.1 Outline MAC address Date Rate 1: Reserved 2: EV 125K 250K 500K 3: GND 4: SG- AD D1 ADD2 BAUD 5: SG+ CME-DN01 6: Reserved 7: Reserved 8: Reserved Empty CAN-H CAN-L 2.2 Description Bi colors LEDs provide users to analyze DeviceNet network and get the (LED Network, LED Module status of the AC motor drive to solve the problem from the...
  • Page 8: Network Example

    Chapter 2 Overview| CME-DN01 2.3 Network Example Power Supply trunk line TR: terminating resistor : device node 2.4 The Distance of Trunk Line The distance between any two points must not exceed the maximum cable distance allowed for the data. Refer to following table for details. Maximum Maximum Maximum...
  • Page 9: Installation

    Chapter 2 Overview| CME-DN01 NOTE: Please refer to the "Appendix B -- DeviceNet Cable Profiles" in the DeviceNet Specifications for the wiring cable to ensure the max. distance. 2.6 Installation STEP 1 STEP 2 STEP 3 STEP 4 Revision September 2017, 2006PDD23000003...
  • Page 10 Chapter 2 Overview| CME-DN01 This page intentionally left blank Revision September 2017, 2006PDD23000003...
  • Page 11: Chapter 3 Quick Start

    Step 4. Using RJ11 (6 pins) to connect RS-485 of the CME-DN01 and the AC drive. Step 5. Adding the EDS files (generated from the auto EDS generator software, can be downloaded from Delta website http://www.delta.com.tw/industrialautomation/) into DeviceNet management software.
  • Page 12: Eds File Description

    Chapter 3 Quick Start| CME-DN01 3.2 EDS File Description ® Function: it is used in the DeviceNet management software tool, such as RSNetWorx of RA. It is used to distinguish which VFD type it connects and modify the VFD settings. To use proper EDS file, please check the AC drives type and firmware version from the parameter first.
  • Page 13: Input/Output Data

    Chapter 3 Quick Start| CME-DN01 Address Description All addresses should be set within this range. Before setting address, please make sure that the address you want to use is 0-63 available (NOT used by others). The address cannot be used repeatedly.
  • Page 14 Chapter 3 Quick Start| CME-DN01 This page intentionally left blank Revision September 2017, 2006PDD23000003...
  • Page 15: Chapter 4 Configuration

    Chapter 4 Configuration CME-DN01 also provides other functions for user to set by requirement. CME-DN01 supports an Object named DataConf (0x95), this object can be accessed via DeviceNet configuration or management tools. DataConf Object is defined as follows: Class 0x95 Data Configure Class Attributes Attribute ID Access Rule...
  • Page 16 Chapter 4 Configuration| CME-DN01 Attribute Access Name Data Type Description Rule word input data Get/Set Data_in[1] UINT word input data Get/Set Data_in[2] UINT word input data Get/Set Data_in[3] UINT word input data Get/Set Data_in[4] UINT word input data Get/Set Data_in[5] UINT word input data Get/Set...
  • Page 17 Chapter 4 Configuration| CME-DN01 data_out1~data_out8: used to save 16 bytes data of each Modbus address of AC drive. For example, if address data in data_out1 is 0x2000, it will send the first word of data to AC drive address 0x2000. Similarly, if address data in data_in1 is 0x2101, CME-DN01 will send the first word of data in AC drive address 0x2101 to DeviceNet network.
  • Page 18 Chapter 4 Configuration| CME-DN01 Attribute ID Name Value(Hex) data_in[0] 2000H data_in[1] 2001H data_in[2] 2002H data_in[3] 0000H data_in[4] 2000H data_in[5] 2001H data_in[6] 2002H data_in[7] 0000H data_out[0] 2101H data_out[1] 2103H data_out[2] 2104H data_out[3] 010AH data_out[4] 2101H data_out[5] 2103H data_out[6] 2104H data_out[7] 010AH Revision September 2017, 2006PDD23000003...
  • Page 19: Chapter 5 Troubleshooting

    Chapter 5 Troubleshooting This chapter provides LEDs information, and corrective actions for solving problem. MAC address Date Rate 1: Reserved 2: EV 125K 250K 500K 3: GND 4: SG- ADD1 ADD2 BAUD 5: SG+ CME-DN01 6: Reserved 7: Reserved 8: Reserved Empty CAN-H CAN-L...
  • Page 20: Module Led

    Chapter 5 Troubleshooting| CME-DN01 State Indication Corrective Actions Ensure that all nodes have unique address. If all node addresses are unique, check Network failure. Failed Red LED network for correct media installation. duplicate ID or Bus-off. Ensure that the address is NOT in the illegal range.
  • Page 21 Chapter 5 Troubleshooting| CME-DN01 State Indication Corrective Actions To check if the connection between the AC drive and RS-485 of CME-DN01 is correct. Connection failure/no Red LED connection Re-wire the AC drive connection and ensure that the wire specification is correct. Revision September 2017, 2006PDD23000003...
  • Page 22 Chapter 5 Troubleshooting| CME-DN01 This page intentionally left blank Revision September 2017, 2006PDD23000003...
  • Page 23: Appendix A Installation Information

    Appendix A Installation Information Appendix A provides the information that you may need to install the CME-DN01. A.1 Dimension 125K 250K 500K N ET M OD ADD1 AD D2 BAUD CME-DN01 72.2 [2.84] 35.8 [1.41] 3.5 [0.14] UNIT: mm(inch) A.2 Ambient Conditions Operation: Temperature: -10 C to 40...
  • Page 24: Product Certifications

    Appendix A Installation Information| CME-DN01 A.3 Product Certifications This product meets the following certifications. Certifications Description UL508C EN50178 and EN61800-3 Revision September 2017, 2006PDD23000003...
  • Page 25: Appendix B Devicenet Object

    Vendor ID Response data Value Description Service 0x8E Successful data 0x031F ID = 0x031F(Delta) Object Classes CME-DN01 supports following object classes and user can read or write them via the DeviceNet management tool. Class Object 0x01 Identity Object 0x02 Message Router Object...
  • Page 26 Appendix B DeviceNet Object| CME-DN01 Class 0x01 Identity Object This object provides identification and general information about the device. Class Attributes Attribute ID Access Rule Name Data Type Revision UINT MaxInstance UINT NumberofInstances UINT MaxIdClass UINT MaxIdInstance UINT Instance 1: Drive Instance Attribute ID Access Rule Name...
  • Page 27 Appendix B DeviceNet Object| CME-DN01 Class 0x02 Message Router The Message Router Object provides a messaging connection point to serve any object class or instance in the Client. Class attributes Attribute ID Access Rule Name Data Type Revision UINT MaxIdClass UINT MaxIdInstance UINT...
  • Page 28 Appendix B DeviceNet Object| CME-DN01 Class 0x03 DeviceNet Object The DeviceNet Object provides the configuration and status of a DeviceNet port. Each CME-DN01 supports one DeviceNet object for a physical connection to the DeviceNet communication link. Class Attributes Attribute ID Access Rule Name Data Type...
  • Page 29 Appendix B DeviceNet Object| CME-DN01 Class 0x05 Connection Object The Connection Class allocates and manages the internal resources associated with both I/O and Explicit Messaging Connections. The specific instance generated by the Connection Class is called a Connection Instance or a Connection Object. Class attributes Attribute ID Access Rule...
  • Page 30 Appendix B DeviceNet Object| CME-DN01 Instance 2: Polled I/O Connection Attribute Access Data Name Rule Type State USINT InstanceType USINT TransportClassTrigger USINT ProducedConnectionId UINT ConsumedConnectionId UINT InitialCommCharacteristics BYTE ProducedConnectionSize UINT ConsumedConnectionSize UINT Get/Set ExpectedPackedRate UINT Get/Set WatchdogTimeoutAction USINT Produced Connection Path USINT Length Produced Connection Path...
  • Page 31 Appendix B DeviceNet Object| CME-DN01 Class 0x0F Parameter Object Use of the Parameter Object provides a known, public interface to a device’s configuration data. In addition, this object also provides all the information necessary to define and describe the device’s individual configuration parameters.
  • Page 32 Appendix B DeviceNet Object| CME-DN01 Instance: Parameter Instance Attribute ID Access Rule Name Data Type Get/Set Parameter Value Link Path Size USINT Link Path Descriptor WORD Data Type USINT Data Size USINT Common Services Implemented for Service Code Service Name Class Instance 0X05...
  • Page 33 Appendix B DeviceNet Object| CME-DN01 Class 0x95 DataConf Object Class attributes Attribute ID Access Rule Name Data Type Revision UINT Instance 1 Attribute Access Name Data Type Description Rule 0: CME-DN01 will use this object for I/O message Get/Set Config_flag USINT 1: CME-DN01 use default setting.
  • Page 34 Appendix B DeviceNet Object| CME-DN01 Attribute Access Name Data Type Description Rule word input data Get/Set Data_in[1] UINT word input data Get/Set Data_in[2] UINT word input data Get/Set Data_in[3] UINT word input data Get/Set Data_in[4] UINT word input data Get/Set Data_in[5] UINT word input data...
  • Page 35: Appendix C Auto Eds Generator Software

    Appendix C Auto EDS Generator Software For correct display the drive that connected to the CME-DN01 in the DeviceNet management tool, we can generate the EDS file for the drive by using the software “Auto EDS Generator”. The operation steps are shown in the following. Step1.
  • Page 36 Appendix C Auto ED S Generator Software|CME-DN01 Step3. After pressing the 【Start】button at the upper-left corner, program will start generating the EDS file as shown in the following. Revision September 2017, 2006PDD23000003...
  • Page 37 Appendix C Auto EDS Generator Software|CME-DN01 Step4. After generating EDS file, you will get a pop-up window for saving this EDS file. Revision September 2017, 2006PDD23000003...
  • Page 38 Appendix C Auto EDS Generator Software|CME-DN01 This page intentionally left blank. Revision September 2017, 2006PDD23000003...

Table of Contents