CME-DN01 also provides other functions for user to set by requirement. CME-DN01 supports an
Object named DataConf (0x95), this object can be accessed via DeviceNet configuration or
management tools. DataConf Object is defined as follows:
Class 0x95 Data Configure
Class Attributes
Attribute ID
1
Instance 1
Attribute
Access
ID
Rule
2
Get/Set
3
Get/Set
4
Get/Set
5
Get/Set
17
Get/Set
18
Get/Set
19
Get/Set
20
Get/Set
21
Get/Set
22
Get/Set
23
Get/Set
24
Get/Set
25
Get/Set
26
Get/Set
Revision September 2017, 2006PDD23000003
Access Rule
Get
Name
Data Type
Config_flag
USINT
NetCtrl
USINT
NetRef
USINT
LossDNTreat
USINT
Dlen_out
USINT
Dlen_in
USINT
Data_out[1]
UINT
Data_out[2]
UINT
Data_out[3]
UINT
Data_out[4]
UINT
Data_out[5]
UINT
Data_out[6]
UINT
Data_out[7]
UINT
Data_out[8]
UINT

Chapter 4 Configuration

Name
Revision
Description
0: CME-DN01 will use this object for I/O
message
1: CME-DN01 use default setting.
0: controlled local.
1: controlled by network.
0: set speed local,
1: set speed by network.
0: Ignore and continue
1: Stop according to "Stop method".
Length of output data
Length of input data
word output data
st
1
word output data
nd
2
word output data
rd
3
word output data
th
4
word output data
th
5
word output data
th
6
word output data
th
7
word output data
th
8
Data Type
UINT
4-1

Advertisement

Table of Contents
loading

Table of Contents