Page 1
OPERATION MANUAL MODEL FX VIBRATOR (Used with FU162A High Frequency Inverter) Revision #0 (05/12/22) To find the latest revision of this publication or associated parts manual, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
To reduce risk of injury user Indicates a hazardous situation which, if not avoided, must read instruction manual COULD result in MINOR or MODERATE INJURY. NOTICE Addresses practices not related to personal injury. PAGE 6 — FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22)
Page 7
No one other than the operator is to be in the working area when the equipment is in operation. DO NOT use the equipment for any purpose other than its intended purposes or applications. FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22) — PAGE 7...
Page 8
ALWAYS make sure the ON/OFF switch on the electric motor is in the OFF position when not in use and before inserting the power plug into an AC receptacle. PAGE 8 — FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22)
Page 9
ALWAYS make certain that proper power or extension cord has been selected for the job. Use only extension cords that are intended for outdoor use and so marked. FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22) — PAGE 9...
20 ft (6 m) 20 ft (6 m) 20 ft (6 m) Cord Length (D) 50 ft (15 m) 50 ft (15 m) 50 ft (15 m) 50 ft (15 m) FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22) — PAGE 11...
13. Case Joint — Secures eccentric case to motor case. 6. Push Cover — Covers the switch box. 7. Cord Armor — Protects power cord connection to the switch box. FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22) — PAGE 13...
POWER SOURCE The FX Vibrators use the FU162A high-frequency inverter as the power source. Refer to the FU162A Operation Manual for more information. PAGE 14 — FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22)
5. The vibrator should be inserted at an interval of 11.8 to 19.7 inches (30 to 50 cm) for about 30 seconds. FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22) — PAGE 15...
Table 5. Current Measurements MODEL FX30E6 FX40G6 FX50G6 FX60E6 4 - 4.5 A 6 - 7 A 9 - 10 A CURRENT or less or less or less or less PAGE 16 — FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22)
Page 17
7. With the switch turned on, check the insulation resistance between the plug terminal and vibration 0.88 0.422 0.189 switch box. RESISTANCE ohms ohms ohms ohms 8. With the switch turned off, check the insulation FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22) — PAGE 17...
Replace. High noise level. Wear of pendulum and rotor joint part? Replace. Wear of motor case bearing mating surface? Replace. Wear of case joint bearing mating surface? Replace. PAGE 18 — FX VIBRATOR • OPERATION MANUAL — REV. #0 (05/12/22)
Page 20
OPERATION MANUAL HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Inc. (310) 537- 3700 6141 Katella Avenue Suite 200 Cypress, CA 90630 E-MAIL: mq@multiquip.com WEBSITE: www.multiquip.com UNITED KINGDOM CANADA Multiquip Multiquip (UK) Limited Head Offi...