  • Page 1 4K / UHD HDMI to HDBaseT Distribution Amplifier Atlona Manuals AT-UHD-CAT-4ED Distribution Amplifiers...
  • Page 2 Version Information Version Release Date Notes Mar 2019 New format Mar 2021 Included instructions for Updating the Valens Firmware (page 39). Apr 2022 Corrected wiring instructions for IR control of source and sink devices. AT-UHD-CAT-4ED...
  • Page 3 Sales, Marketing, and Customer Support Main Office International Headquarters Atlona Incorporated Atlona International AG 70 Daggett Drive Tödistrasse 18 San Jose, CA 95134 8002 Zürich United States Switzerland Office: +1.408.962.0515 Office: +41.43.508.4321 Sales and Customer Service Hours Monday - Friday: 6:00 a.m. - 4:30 p.m. (PST) Sales and Customer Service Hours Monday - Friday: 09:00 - 17:00 (UTC +1) https://atlona.com/...
  • Page 4 Safety and Certification 9. Do not defeat the safety purpose of a polarized CAUTION or grounding-type plug. A polarized plug has two RISK OF ELECTRIC SHOCK blades with one wider than the other. A grounding DO NOT OPEN type plug has two blades and a third grounding CAUTION: TO REDUCT THE RISK OF prong.
  • Page 5: Table Of Contents

    Table of Contents Introduction Features Package Contents Panel Description Installation Connection Instructions Connection Diagram IP Configuration Setting the IP Mode Setting the IP Address Using Commands Setting the IP Address using the Web Server Device Operation LED Indicators Locking the Front Panel Using the Front Panel Using the web server EDID Management...
  • Page 6: Introduction

    Introduction The Atlona AT-UHD-CAT-4ED distribution amplifier featuring pass-through HDMI input connections, four extended distance, Ethernet-enabled HDBaseT outputs and display control capability. Each output transmits AV and control signals up to 330 ft. (100 m). Features include 4K/UHD @ 60 Hz with 4:2:0 color subsampling, HDCP 2.2 compliance, EDID management, and PoE for powering remote receivers.
  • Page 7: Panel Description

    Panel Description HDMI HDBaseT LOCK INT LEARN HDMI HDBaseT LOCK INT LEARN AT-UHD-CAT-4ED POWER EDID AT-UHD-CAT-4ED POWER EDID MASTER MASTER RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 HDMI HDBaseT OUT DC 48V HDMI HDBaseT OUT DC 48V HDMI Indicators Displays the status of the HDMI IN and HDMI OUT Connect an Ethernet cable from this port to the...
  • Page 8: Installation

    Installation Connection Instructions 1. Connect an HDMI cable from a UHD/HD source to the HDMI IN port. 2. Connect an HDMI cable from the HDMI OUT port to a display (sink) device. 3. Connect up to four Ethernet cables from the HDBaseT OUT ports to compatible PoE-capable receivers. Refer to the table below for information on maximum cable length and supported resolutions.
  • Page 9: Connection Diagram

    Installation Connection Diagram Display LE AR IN T se T W ER -4 ED -C AT AT -U AT-UHD-CAT-4ED Laptop -R X X -7 D -E A T- W ER LI N AT-UHD-EX-70C-RX -R X X -7 D -E A T- W ER LI N AT-UHD-EX-70C-RX...
  • Page 10: Ip Configuration

    Installation IP Configuration The AT-UHD-CAT-4ED is shipped with DHCP enabled. Once connected to a network, the DHCP server (if available), will automatically assign an IP address to the unit. Use an IP scanner, along with the MAC address on the back of the unit, to identify both the unit and its IP address on the network.
  • Page 11: Setting The Ip Address Using The Web Server

    Installation 3. Execute the IPStatic command. This command requires three arguments: the desired IP address of the AT- UHD-CAT-4ED, the subnet mask, and the gateway address. All arguments must be entered in dot-decimal notation. The following is an example: IPStatic 192.168.1.112 255.255.255.0 192.168.1.1 IP address Subnet mask Gateway...
  • Page 12: Device Operation

    Device Operation LED Indicators The LED indicators on both the front of the unit provide basic information on the current status of the AT-UHD-CAT- 4ED. Description POWER Blue Unit is powered and in normal operating mode. Unit is in standby mode. •...
  • Page 13: Locking The Front Panel

    Device Operation Locking the Front Panel The buttons on the front panel can be locked or unlocked. Locking the front-panel buttons prevents accidental pressing of the buttons, which may occur when the unit is mounted in a rack environment. Locking and unlocking of the front-panel buttons is managed through the web server or by executing the Lock and Unlock API commands.
  • Page 14: Edid Management

    Device Operation EDID Management The AT-UHD-CAT-4ED provides two EDID modes: INT and LEARN. The default EDID mode is INT mode. In this mode, the AT-UHD-CAT-4ED will automatically create an EDID based on the capabilities of all connected displays. INT mode is recommended for the best results when the capabilities of all connected displays are unknown. INT mode can also be used to select any of 16 EDID presets.
  • Page 15: Learning The Edid Using The Web Server

    Device Operation Learning the EDID using the web server 1. Follow steps 1 through 3 under Learning an EDID using the Front Panel (page 14). 2. Login to the web server. Refer to Introduction to the Web Server (page 29) for more information.
  • Page 16: Selecting Edid Presets

    Device Operation Selecting EDID Presets The AT-UHD-CAT-4ED comes with a default EDID plus 16 pre-programmed EDID selections. When selecting the default or one of the pre-programmed EDID selections, the EDID mode must be set to INT (internal) mode. Available EDID selections are presented in the table below. EDID ATL 1280x800 RGB 2CH ATL 1080P 2CH...
  • Page 17: Managing Users

    Device Operation Managing Users The AT-UHD-CAT-4ED allows the admin user to create, edit, and remove additional TCP/IP users. All users have the same level of access to control the AT-UHD-CAT-4ED. However, only the admin user is allowed to manage other users.
  • Page 18: Editing / Deleting Users

    Device Operation Editing / Deleting Users The username and password of a user can be changed using this method. 1. Open the desired web browser and enter the IP address of the AT-UHD-CAT-4ED. 2. Log in as the admin user with the required credentials. The factory-default username and password for the admin user are listed below: Username: root Password: Atlona...
  • Page 19: Rs-232 Control

    Device Operation RS-232 Control The AT-UHD-CAT-4ED provides two methods of RS-232 control: Pass-through mode and control mode. The master RS-232 / IR port, allows the unit to be directly controlled using a control system. In addition four pass-through RS- 232 / IR ports allow sink devices, at the viewing location, to be controlled using a control system. 1 2 3 4 5 RS-232 is serial data protocol that allows Data Terminal Equipment (DTE) devices, such a computer or control system, to communicate with Data Communication Equipment (DCE) devices, such as the AT-UHD-CAT-4ED or a...
  • Page 20: Cable Assembly

    Device Operation Cable Assembly When connecting a DTE device to a DCE device, a straight-through cable should be used. A straight-through cable is wired in such a way that the pins on one side of the cable are connected to the corresponding pins on the opposite side of the cable, as shown in the table below.
  • Page 21: Pass-Through Mode

    Device Operation Pass-through mode In pass-through mode, RS-232 commands are passed-through the AT-UHD-CAT-4ED, transmitted over HDBaseT to a receiver unit, and then to the display (sink) device. Note that each RS-232 / IR port is assigned to an HDBaseT OUT port. This assignment is fixed and cannot be changed, as shown in the table below. RS-232 / IR Port HDBaseT Port RS-232 / IR Port...
  • Page 22: Control Mode

    Device Operation Control mode In control mode, the MASTER RS-232 / IR port is used to directly control the AT-UHD-CAT-4ED using a control system. 1. Launch a web browser and login to the web server. Refer to Introduction to the Web Server (page 29) for more information.
  • Page 23: Ir Control

    Device Operation IR Control IR can be used to control either source devices at the headend or devices connected to the receiver endpoint, such as a display. Note that the MASTER RS-232 / IR port does not support IR control. Note that each RS-232 / IR port is assigned to an HDBaseT OUT port.
  • Page 24: Controlling Source Devices

    Device Operation Controlling Source Devices 1. Remove at least 3/16” (5 mm) of insulation from the RX and GND wires of the emitter. HDMI HDBaseT LOCK INT LEARN 2. Locate the included 5-pin captive screw block and open each of the terminals by turning the screws counter- clockwise, using a small regular screwdriver.
  • Page 25: Power Button Modes

    Device Operation Power Button Modes The main function of the POWER button on the front panel is to toggle the AT-UHD-CAT-4ED between standby and normal operating mode. This is the default mode. However, this button can also be defined to send CEC power- on and power-off commands, over HDBaseT, to the display (sink) devices.
  • Page 26: Powering Sink Devices

    Device Operation Powering Sink Devices This section provides information on how to power-on / power-off the display (sink) device, using the POWER button. CEC* power-on / power-off commands are transmitted over all HDBaseT OUT ports, as well as the pass- through HDMI OUT port.
  • Page 27 Device Operation 6. Test the CEC power-on and power-off commands by pressing the ON and OFF buttons, near the bottom of the page. 7. Press the POWER button on the front panel to power-on or power-off the display. Note that the power state of the AT-UHD-CAT-4ED will be unaffected.
  • Page 28: Powering Sinks And The At-Uhd-Cat-4Ed

    Device Operation Powering Sinks and the AT-UHD-CAT-4ED In this mode, the POWER button will power-on / power-off the unit and the connected displays. CEC* power-on / power-off commands are transmitted over all HDBaseT OUT ports. 1. Make the proper connections by following steps 1 through 4, under Powering Sink Devices (page 26).
  • Page 29: The Web Server

    The Web Server Introduction to the Web Server The AT-UHD-CAT-4ED includes a built-in web server. Atlona recommends that the web server be used to set up the AT-UHD-CAT-4ED, as it provides intuitive management of all features. The AT-UHD-CAT-4ED is shipped with DHCP enabled. Once connected to a network, the DHCP server will automatically assign an IP address to the unit.
  • Page 30 The Web Server 7. The Info page will be displayed. 8. Click Logout, on the far-right side of the menu bar, to log out of the web server and return to the Login page. AT-UHD-CAT-4ED...
  • Page 31: Info Page

    The Web Server Info page Model Name The model SKU of this product. Software Version The version of firmware that the AT-UHD-CAT-4ED is running. Always make sure to check the AT-UHD-CAT-4ED product page, on the Atlona web site, for the latest version of firmware. Output 1 VALENS Version - Output 4 VALENS Version The version of firmware on the HDBaseT chip for each HDBaseT OUT port.
  • Page 32: Rs-232 Page

    The Web Server RS-232 page RS-232 Parameter Setting Click each of these drop-down boxes to select the desired baud rate, data bits, parity bit, and stop bit for the MASTER RS-232 / IR port. Setting Description Baud rate Sets the baud rate. The following options are available: 2400, 9600, 19200, 38400, 56000, 57600, 115200.
  • Page 33: Edid Page

    The Web Server EDID page EDID lock Click this toggle to switch the EDID lock mode. When set to the LOCK position, EDID mode Click this drop-down list to select the desired EDID mode. EDID mode Description Internal mode. Uses the default internal EDID LEARN Learn mode.
  • Page 34: Config Page

    The Web Server Config page Old Username This field cannot be changed. “root” is the administrator user. Old Password Enter the current password for the “root” username in this field. The default password is “Atlona”. New Username This field cannot be changed. Save Click this button to save all changes.
  • Page 35: System Page

    The Web Server System page IP Mode Click this toggle to set the IP mode of the AT-UHD-CAT-4ED. The default setting is DHCP. Available settings: STATIC IP, DHCP. Enter the IP address of the AT-UHD-CAT-4ED in this field. This field will only be available if IP Mode is set to STATIC IP.
  • Page 36 The Web Server Power Under normal operation conditions, this toggle is set to ON. Click this toggle to OFF, to place the AT-UHD-CAT-4ED in standby mode. The PWOFF and PWON commands can also be used to control the power state. Lock Click to lock or unlock the buttons on the front panel.
  • Page 37: Appendix

    Appendix Updating the MCU Firmware Updating the MCU firmware can be completed using either the USB interface or the web server. Atlona recommends using the web server for updating the MCU firmware. However, if a network connection is not available, the AT-UHD- CAT-4ED MCU firmware can be updated using a USB-A to USB mini-B cable.
  • Page 38: Using Usb

    Appendix Using USB Required items: • AT-UHD-CAT-4ED • Computer containing the firmware file. • USB-A to USB mini-B cable 1. Disconnect power from the AT-UHD-CAT-4ED. 2. Press and hold the POWER button while connecting power to the AT-UHD-CAT-4ED. 3. Release the POWER button. The POWER button will glow solid red, indicating that the AT-UHD-CAT-4ED is in update mode.
  • Page 39: Updating The Valens Firmware

    Appendix Updating the Valens Firmware Updating the Valens firmware can be completed using either the USB interface or the web server. Atlona recommends using the web server for updating the Valens firmware. However, if a network connection is not available, the AT-UHD-CAT-4ED Valens firmware can be updated using a USB-A to USB mini-B cable. Using the Web Server Requirements: •...
  • Page 40: Using Usb

    Appendix Using USB Required items: • AT-UHD-CAT-4ED • Computer containing the firmware file. • USB-A to USB mini-B cable 1. Disconnect power from the AT-UHD-CAT-4ED. 2. Press and hold the EDID button while connecting power to the AT-UHD-CAT-4ED. 3. Release the EDID button. The POWER button will glow solid red, indicating that the AT-UHD-CAT-4ED is in update mode.
  • Page 41: Cable Termination

    Appendix Cable Termination Atlona recommends EIA/TIA-568-B termination. Connector type and size is very important to ensure extenders work correctly. Always use the matching cable type with the correct RJ45 connector. • CAT5e cables should use only CAT5e RJ45 connectors • CAT6 cables should use only CAT6 connectors •...
  • Page 42: Default Settings

    Appendix Default Settings The following tables list the factory-default settings for the AT-UHD-CAT-4ED. Feature Settings RS-232 Baud rate 115200 Data bit Parity None Stop bit EDID EDID lock UNLOCK EDID mode INT EDID settings Config Username (default) root Password (default) Atlona System IP Mode...
  • Page 43: Specifications

    Appendix Specifications Video Signal Input - HDMI Output - HDMI / HDBaseT Copy Protection Pixel Clock 300 MHz UHD/HD/SD 4096x2160 (DCI) @ 24/25/30 Hz 720x576p @ 50 Hz 3840x2160 (UHD) @ 24/25/30 Hz 720x576i @ 50 Hz 1920x1080p @ 23.97/24/25/29.97/30/50 720x480p @ 59.94/60 Hz /59.94/60 Hz 640x480p @ 60 Hz...