1. USE
This device automatically controls a light source by detecting movement
in its supervision zone.
Movement detector with 360° detection angle
Detection methods: infrared (PIR) and ultrasound (US)
Mounting: ceiling
2. TECHNICAL DATA
Voltage: 100 - 240 V~
Frequency: 50 / 60 Hz
No-load power consumption: 0.8 W
Output by normally open contact connected to phase
Cabling: 2 x 2.5 mm
2
Flush-mounting diameter: 65 mm without flush-mounting box,
68 mm with flush-mounting box
Weight: 162 g
Impact resistance: IK04
Penetration by solid/liquid bodies: IP20
Operating temperature: - 5°C to + 45°C
Storage temperature: - 20°C to + 70°C
Cover removed
PIR Detector
Green detection
indicator light
IR reception LED
(for configuration tool
or remote control)
1
Incandescent lamp
2
Halogen lamp
3
Halogen lamp with separate ferromagnetic or electronic transformer
4
Fluorescent tubes
5
Compact fluorescent lamp with integrated ballast
6
Compact fluorescent lamp with separate ferromagnetic or electronic ballast
7
Contactors
1
230 V~
2000 W
8.5 A
110 V~
1000 W
8.5 A
Technical data sheet: F01013EN/01
CONTENTS
LEARN key
Green programming
indicator light
US Detector
Protective shield
IR transmission LED
(for configuration tool)
2
3
2000 W
8.5 A
1000 VA
4.3 A
1000 W
8.5 A
500 VA
4.3 A
Updated: 31/05/2010
87045 LIMOGES Cedex
Telephone : 33 5 55 06 87 87 - Fax: 33 5 55 06 88 88
Cat. No(s): 488 06
3. OVERALL DIMENSIONS
Without protective cover
50
With protective cover
65
4
5
10x(2x36 W) 4.3 A
500 VA
5x(2x36 W)
4.3 A
250 VA
CONTENTS
1. Use. . . . . . . . . . . . . . . . . . . . . . . . . . .1
2. Technical data . . . . . . . . . . . . . . . . . .1
3. Overall dimensions. . . . . . . . . . . . . . .1
4. Connection . . . . . . . . . . . . . . . . . . . . .2
5. Installation . . . . . . . . . . . . . . . . . . . . .2
6. Removal . . . . . . . . . . . . . . . . . . . . . . .2
7. Settings . . . . . . . . . . . . . . . . . . . . . . .3
8. Performance. . . . . . . . . . . . . . . . . . . .4
9. Cleaning . . . . . . . . . . . . . . . . . . . . . . .4
10. Standards . . . . . . . . . . . . . . . . . . . . . .4
59
82
6
7
2.1 A
1000 VA
4.3 A
I max.  2A
2.1 A
500 VA
4.3 A
Created: 29/09/2009
Page
1/4

Advertisement

loading

Summary of Contents for LEGRAND 488 06

  • Page 1 87045 LIMOGES Cedex Telephone : 33 5 55 06 87 87 - Fax: 33 5 55 06 88 88 Dual Tech detector switch Cat. No(s): 488 06 CONTENTS Page 1. Use......1 2.
  • Page 2 Dual Tech detector switch Cat. No(s): 488 06 4. CONNECTION 5. INSTALLATION Number of terminals: 4 Terminal type: automatic Terminal capacity: 2 x 2.5 mm 0.3 to 30 mm Stripping length: 8 mm Ø 68 Ø 65 Cabling with auxiliary control : Manual on/Auto off 8.5 A...
  • Page 3 Dual Tech detector switch Cat. No(s): 488 06 7. SETTINGS 7. SETTINGS (cont.) - Parameters: - Modifying parameters using configuration tools Sensor parameters Default Modifiable parameters Configuration value tools 88230 88235 3,5,10,15,20 min − Time delay 15 mn 0 - 59 min 59s −...
  • Page 4 Dual Tech detector switch Cat. No(s): 488 06 8. PERfORMANCE 9. CLEANING Ensure the lens remains clean. Height Surface cleaning using a cloth. Do not use: acetone, tar remover, trichloroethylene. Resistant to the following products: - Hexane (EN 60669-1), - Methylated spirit,...