Starting and stopping Bluetooth low energy technology Advertising
Format: cmd 0x08 0x000A n
Function: Starting and stopping transmission of the Advertising packet.
Parameter n
Length
00
2 characters
01
2 characters
When specifying a start point, make sure you start Advertising using this command before
low energy technology Advertising Packet specifications" on page
Device address specifications
Format: cmd 0x08 0x0005 n6 n5 n4 n3 n2 n1
Function: Specify a BD Address. Specify a value in Little Endian.
As a Random Static Address is used in the printer, bit7 and bit6 for n1 need to be set to 1.
Bluetooth low energy technology Advertising parameter specifications
Format: cmd 0x08 0x0006 aL aH bL bH c d e f1 f2 f3 f4 f5 f6 g h
Function: Sets a variety of parameters for the Advertising packet.
Definition
Min advertising Interval
Max advertising Interval
Advertising type
Own address type
Peer address type
Peer address
Advertising channel map
Advertising filter policy
See the Bluetooth specifications for details.
Function
Advertising stop
Advertising start
Length
Default
2 bytes
aL: a0
aH: 00
2 bytes
bL: a0
bH: 00
1 bytes
c: 03
1 bytes
d: 01
1 bytes
e: 00
6 bytes
f1-f6: 00
1 bytes
g: 07
1 bytes
h: 02
"Bluetooth
130.
Description
00a0h * 0.625 = 100ms Period
00a0h is the minimum that can be
specified.
00a0h * 0.625 = 100ms Period
00a0h is the minimum that can be
specified.
03h: ADD_NONCONN_IND
01h: random device address
00h: public device address
No use
07h: All channel enabled
02h: Process scan requests from all
devices and only connection requests
from devices that are in the White List.
Appendix