Download Print this page
Heatstore HSAC6000X Installation, Operation And Maintenance Instructions

Heatstore HSAC6000X Installation, Operation And Maintenance Instructions

Warm air curtain heaters

Advertisement

Quick Links

Avon Riverside, Victoria Road, Avonmouth, Bristol BS11 9DB
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR
WARM AIR CURTAIN HEATERS
MODEL
This unit is a 902mm 6kW modular heater designed for mounting
above doorways and similar entrances, and may be used as space
heaters.
MOUNTING
When mounted over a standard shop doorway the unit should be
fitted as low as possible and not more than 2.3 meters from ground
level. A single unit will provide reasonable coverage for a one metre
doorway, and for wider doorways units can be mounted end to end.
The unit should be positioned so that the airflow is not obstructed by
any part of the doorframe.
INSTALLATION
Carefully unpack the unit and remove the top cover fixing screws.
The heater may be mounted using the mounting bracket provided.
Remove mounting bracket screws, allowing the mounting bracket to
be removed from the unit. Making sure that the mounting bracket is
horizontal, fix the bracket to the wall using 4 x No 8 wood screws.
Place the unit on the mounting bracket ensuring the washer is
positioned as in diagram.
Telephone: 0117 923 5375
Catalogue Number HSAC6000X
PLEASE RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE
Fig 1 - OUTLINE DRAWING
Fax: 0117 923 5374
Tighten screws to hold the unit at the required angle.
WALL BRACKET ASSEMBLY
Fig 2
The heater may also be mounted directly onto a suitable wall or
bearer by four No 8 wood screws through the holes provided in the
back of the unit casing. Keyhole slots are provided for the top two
fixings (fig 1).
ELECTRICAL CONNECTIONS
This unit is suitable for connection to a 230/240 volt 50 Hz single
phase ac supply.
The heater consumes 6kW at 240 volts when
switched to the full heat position.
The appliance should be connected to the supply via a circuit in
which there is an all-pole switch. Test for correct operation and
refit the cover.
41000956 Iss 01

Advertisement

loading

Summary of Contents for Heatstore HSAC6000X

  • Page 1 Telephone: 0117 923 5375 Fax: 0117 923 5374 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR WARM AIR CURTAIN HEATERS Catalogue Number HSAC6000X PLEASE RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE MODEL Tighten screws to hold the unit at the required angle. This unit is a 902mm 6kW modular heater designed for mounting above doorways and similar entrances, and may be used as space heaters.