System Startup; Filter Changes - NU Aqua Platinum Series Installation Manual

Hide thumbs Also See for Platinum Series:
Table of Contents

Advertisement

System Startup

WARNING:
Before sending any water through your system fully check every connection
on the system. Remove any retaining clips and push the tubing into the quick
connect to ensure its fully inserted. Reinstall each retaining clip.
NOTE: DO NOT DRINK ANY WATER UNTIL COMPLETING THE FLUSHING PROCESS BELOW.
1.
Turn the valve on your tank to the off position. This is to prevent any loose filters media from entering
your tank.
2. Open your cold water line fully then open your feed water adapter.
3. If your system is equiped with a booster pump plug in the electrical cord into your outlet.
4. If your system is equiped with a UV filter plug the electrical cord into your outlet.
5. Turn the handle on your reverse osmosis faucet to the open position. This may take up to 10 minutes
for water to begin to drip from the faucet. Once water begins to drip, let it run for 30 minutes.
6. After 30 minutes have passed close the reverse osmosis faucet and wait 10 minutes for the system
to pressurize. Once pressurized feel and visually check each fitting and connection for leaks.
If no leaks are present, proceed. If you do have a leak, locate the source and turn off the cold water valve.
Address the leak, if unable to resolve, contact our customer support.
7. Turn the tank ball valve to the open position.
8. Wait for the tank to fill, this will take approximately 1-3 hours.
9. Now that the tank is full, flush the system by opening the reverse osmosis faucet until the storage tank is
completely drained. The water flow will be reduced to a slow trickle once the tank is empty.
10. Repeat steps 6-7 three to five times to ensure your system is properly flushed. Once completed your system
is ready for use.
IMPORTANT: Check for leaks daily during the first two weeks after installation.
NOTE: Your water may have a slightly milky color during the first week of use. This is caused
by tiny air bubbles in the water and will go away with use.
NOTE: If your system has an alkaline filter your water's TDS will register higher. For accurate
testing, test water that has not been processed by the alkaline filter.
24

Filter Changes

WANT YOUR FILTERS DELIVERED AUTOMATICALLY?
JOIN THE FILTER CLUB AND GET YOUR FILTERS
AT A DISCOUNT.
Prefilers Stage 1-3
1. Turn off the cold water valve that your system is connected to and open the reverse osmosis faucet to drain
the system. Unplug your system if it has a booster pump or UV filter.
2. Place your system in a small bucket or water collection tray and loosen stages 1-3 with your housing wrench.
3. Remove and discard the old filters.
4. Using dish soap wash the prefilter housings. Thoroughly rinse the housings to ensure all the soap is removed.
5. Wash your hands before unwrapping and handling your new replacement filters.
6. Unwrap and drop in your new replacement filters in their housing.
7. Before tightening the housings make sure that each housing has it's o-ring in the correct location.
8. Tighten the filter housings using your housing wrench.
9. If you're not replacing any other filters follow the system restart procedure on page 21.
Membrane
1. Turn off the cold water valve that your system is connected to and open the reverse osmosis faucet to drain
the system. Unplug plug your system if it has a booster pump or UV filter.
2. Place your system in a small bucket or water collection tray and loosen stages 1-3 with your housing wrench.
3. Open the membrane housing and pull out the old membrane.
4. Push in the new membrane firmly into the housing. Tighten the housing cap with your housing wrench.
5. If you're not replacing any other filters follow the system restart procedure on page 21.
Post Filter
NOTE: Make sure you've already turned off your system. If not follow step #1 from Prefilters.
1. Disconnect your tubing from both ends of the filter and remove the push fittings from the filter.
2. Remove the old filter from the housing clips and discard.
3. Attach your new post filter to the housing clips in the same orientation as the one previously removed.
4. Reinsert the two push fittings from your older filter and attach your tubing.
5. If you're not replacing any other filters follow the system restart procedure on page 21.
Alkaline Filter
NOTE: Make sure you've already turned off your system. If not follow step #1 from Prefilters.
1. Disconnect your tubing from both ends of the filter and remove the push fittings from the filter.
2. Remove the old filter from the housing clips and discard.
3. Attach your new alkaline filter to the housing clips in the same orientation as the one previously removed.
4. Reinsert the two push fittings from your older filter and attach your tubing.
5. If you're not replacing any other filters follow the system restart procedure on page 21.
UV Filter
NOTE: DO NOT unscrew the UV filters metal cap. This is not needed to change the bulb.
1. Make sure the UV power cord is unplugged from the power outlet.
2. Slide off the black plastic cap off of the UV filter and slide the bulb out of the filter housing.
3. Unplug and discard the old bulb.
4. Connect new bulb to power supply and slide into filter housing. Reinstall black plastic cap.
Scan Me!