Ducting Options (Prior to Installation) (continued)
VENTILATE OUT OF YOUR DWELLING VERTICALLY BY USING THE 7" ROUND AIR VENT (B)
LOCATED ON TOP OF THE RANGE HOOD
1. Remove the (4) set screws from the air vent (B) that is attached to the top of the range hood and remove the air vent.
*Keep the (4) set screws.
2. Using a flat head screwdriver and pliers, remove the 3-1/4" X 10" stainless-steel plate.
3. Using a flat head screwdriver and pliers, remove the half-round stainless-steel plate.
4. Reassemble the air vent (B) to the top of the range hood using the (4) set screws removed in step one.
B
B
10
Ducting Options (Prior to Installation) (continued)
VENTILATE OUT OF YOUR DWELLING VERTICALLY BY USING THE 3-1/4" X 10" AIR VENT (D)
THAT WILL BE ASSEMBLED ON TOP OF THE RANGE HOOD
1. Follow steps 1 and 2 from left. Do not remove the half-round
stainless-steel plate.
VENTILATE OUT OF YOUR DWELLING HORIZONTALLY BY USING THE 3-1/4" X 10" AIR VENT
(D) THAT WILL BE ASSEMBLED TO THE REAR OF RANGE HOOD
1. On the rear of the range hood, remove the two set screws as shown below.
2. Using a flat head screwdriver and pliers, remove the 3-1/4" X 10" stainless-steel plate.
* (2) #8 X 3/8 screws are pre-installed
3. You need to confirm the gap between cabinet and rear exhaust.
- If the gap between cabinet and rear exhaust= 3/8in use 4 screw holes(Fig.3)
- If the gap between cabinet and rear exhaust= 7/8in use 4 screw holes(Fig.4)
Fig.3
2. Attach the 3-1/4" X 10" air vent (D) using the (6) #8 X 3/8
screws(BB).
D
Do not use this hole
Fig.4
11