TRANSPORTATION, HANDLING, INSTALLATION
6.1.4.2 Storage
•
It is preferred that the package be stored in a controlled environment. If this is not possible, as a
minimum it should be protected from the elements with an adequate cover which will not allow
condensate to collect within it.
•
Monthly, rotate the drive shaft 1 1/2 turns in opposite direction to the normal rotation.
•
Maintain motor in accordance with motor manufacturer recommendations during storage period.
6.1.4.3 Startup
•
Follow start-up instructions in the motor manual.
•
Megger the motor. Compare with tag on motor eye-bolt taken at time of storage. See motor
manufacturers recommendations for reference.
•
If water cooled, remove glycol from coolers and associated piping.
•
Remove all plugs where tagged.
•
Manually rotate the motor shaft in the direction of rotation to remove fluid from the airend.
•
Drain the sump and plug.
•
Check minimum pressure valve for free movement.
•
Fill the sump with a fresh charge of compressor fluid.
•
Install air filter, blowdown valve, relief valve, and any other components that were removed in
preparation of, or during, storage.
•
Remove dessicant from starter/control box.
•
Follow the compressor manual for normal start-up procedure.
6.2
Compressor Placement and Connections
Figure 17 Compressor
Placement in Room
35