6.1.4.2 Storage
It is preferred that the package be stored in a controlled environment. If this is not possible, as a
minimum it should be protected from the elements with an adequate cover which will not allow
condensate to collect within it.
Monthly, rotate the drive shaft 1 1/2 turns in opposite direction to the normal rotation.
Maintain motor in accordance with motor manufacturer recommendations during storage period.
6.1.4.3 Startup
Follow start-up instructions in the motor manual.
Megger the motor. Compare with tag on motor eye-bolt taken at time of storage. See motor
manufacturers recommendations for reference.
If water cooled, remove glycol from coolers and associated piping.
Remove all plugs where tagged.
Manually rotate the motor shaft in the direction of rotation to remove fluid from the airend.
Drain the sump and plug.
Check minimum pressure valve for free movement.
Fill the sump with a fresh charge of compressor fluid.
Install air filter, blowdown valve, relief valve, and any other components that were removed in
preparation of, or during, storage.
Remove dessicant from starter/control box.
Follow the compressor manual for normal start-up procedure.