5.1.8
Replacing the water pump
1 Shaped hose, water distribution bar connection
2 Water pump (M2)
Remove the cleaning head housing (see chapter "Re-
moving the cleaning head housing").
Pull the shaped hose off the connection of the water
distribution bar.
Pull the water pump out of the water pump holder to-
ward the top.
1 Shaped hose, water distribution bar connection
2 Water pump (M2)
3 Water hose to the water pump
4 Pump holder, rubber
5 Pump holder, rubber
6 Connector, connecting cable to water pump
7 Diode, soldered into the cable
The rectifier diode converts AC voltage to pulsating direct
voltage. This will result in the water pump feeding the wa-
ter evenly.
The supply voltage can be read at the Molex plug.
Target value:
Water pump switch turned off = 0 V AC
Water pump switch turned on = current voltage
BR 30/4 C Bp Pack
22
English 5.906-768.0 Rev. 01 (10/20)
1 Connecting cable
2 Water hose to the water pump
3 Water pump (M2)
4 Pump holder, rubber
5 Shaped hose, water distribution bar connection
6 Connector, connecting cable to water pump
Pull the shaped hose off the water pump.
Pull the hose off the water pump.
Remove the pump holder from the water pump.
Disconnect the connectors
Install the new water pump in reverse order.
5.1.9
Voltage measurement on the water pump
NOTICE
BR 30/4 C onlyBp Pack:
The connection voltage of 24 Volts is pulsed; therefore,
only about 12 Volts can be measured on the water pump.
This water pump does not have a diode. The water pump
is monitored by current. If the current pickup is too high, it
is switched off.
5.1.10 Replacing the toothed belt
1 Fastening screws (2x), cover
2 Cover
Remove the cleaning head casing (see chapter "Re-
moving the cleaning head casing").
Unscrew the screws.
Remove cover.