Rockwell Automation Allen-Bradley Guardmaster Minotaur MSR127 Installation Instructions

Rockwell Automation Allen-Bradley Guardmaster Minotaur MSR127 Installation Instructions

Monitoring safety relays

Advertisement

Quick Links

Installation Instructions
Original Instructions
MSR127 Minotaur Monitoring Safety Relays
Catalog Number 440R-N23124, 440R-N23125, 440R-N23126, 440R-N23127, 440R-N23128, 440R-N23129, 440R-N23129M, 440R-N23130,
440R­N23131, 440R-N23132, 440R-N23132S, 440R-N23133, 440R-N23134, 440R-N23135, 440R-N23135M, 440R-N23135S, 440R-N23213
Topic
Summary of Changes
Safety
Repair
Functional Description
Specifications
Diagnostics
Safety Input
Reset
Installation
Wiring Examples
Circuit Diagram
Approximate Dimensions
Safety Specifications
Declaration of Conformity
Summary of Changes
This publication contains the following new or updated information. This list
includes substantive updates only and is not intended to reflect all changes.
Topic
Updated Declaration of Conformity
Safety
This device is intended to be part of the safety-related control system of a
machine.
Safety Notes
Before installation, perform a risk assessment to determine whether the
specifications of this device are suitable for all foreseeable operational and
environmental characteristics of the machine to which it is to be fitted. At regular
intervals during the life of the machine, check whether the characteristics
foreseen remain valid.
ATTENTION: Danger of serious injuries.
Misuse can result in malfunction.
• Only authorized and trained personnel must start up,
assemble, install, manipulate, or retrofit the device.
• Installation must be in accordance with these instructions.
• Do not defeat, tamper, remove, or bypass this unit.
Rockwell Automation cannot accept responsibility for failure of this device if the
Page
procedures given in these instructions are not followed or if it is used outside the
1
recommended specifications in these instructions.
1
1
IMPORTANT
The safety inputs of these products are described as
1
normally closed (N.C.), that is, with the guard closed, the
2
actuator in place (where relevant) and the machine able to
be started. Exposure to shock and/or vibration in excess
2
of what is stated in IEC 60068 part: 2-6/7 must be avoided.
2
Adherence to the recommended inspection and
2
maintenance instructions forms part of the warranty.
3
3
Repair
3
3
4
ATTENTION: MSR127 safety relays are not repairable.
4
If there is any malfunction or damage, do not attempt to repair. The unit must be
replaced before machine operation is allowed.
Functional Description
Page
The unit is enabled once the supply is powered up and the safety circuits are
4
closed. The PWR status indicator is on.
A valid reset operation activates the safety outputs. The CH1 and CH2 status
indicators of the output illuminate. At the demand of the safety function and if any
fault occurs, the safety outputs de-energize within the specified response time.
Fault Detection
If a fault occurs, the internal relay circuit forces the safety outputs off. One or both
output status indicators can be off. The PWR status indicator can flash. Remove
the fault and cycle the safety input to re-enable the device. Cycling power to the
safety relay can also clear the fault condition.

Advertisement

loading

Summary of Contents for Rockwell Automation Allen-Bradley Guardmaster Minotaur MSR127

  • Page 1 MSR127 Minotaur Monitoring Safety Relays Catalog Number 440R-N23124, 440R-N23125, 440R-N23126, 440R-N23127, 440R-N23128, 440R-N23129, 440R-N23129M, 440R-N23130, 440R­N23131, 440R-N23132, 440R-N23132S, 440R-N23133, 440R-N23134, 440R-N23135, 440R-N23135M, 440R-N23135S, 440R-N23213 Rockwell Automation cannot accept responsibility for failure of this device if the Topic Page procedures given in these instructions are not followed or if it is used outside the Summary of Changes recommended specifications in these instructions.
  • Page 2 2-channel safety inputs in 4-wire connection (S11-S12, S21-S22). Cross-loop monitoring is disabled for single-channel inputs, dual-channel inputs in 3-wire connection, and 24V DC signals. For external 24V DC signals, the Rockwell Automation Publication 440R-IN079D-EN-P - July 2022...
  • Page 3 14 24 34 42 Table 2 - Status Indicators Status Indicator Description Green: Unit is powered Flashing green: Cross-loop faults Green: Safety output channel 1 is activated Green: Safety output channel 2 is activated Rockwell Automation Publication 440R-IN079D-EN-P - July 2022...
  • Page 4 Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenkÖy, İstanbul, Tel: +90 (216) 5698400 EEE YÖnetmeliğine Uygundur Allen-Bradley, expanding human possibility, Guardmaster, Minotaur, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.