PRECAUTIONS FOR GROUP CONTROL
SYSTEM OR TWO REMOTE CONTROLLERS
CONTROL SYSTEM
This system provides two other control systems
beside individual control (one remote controller
controls one indoor unit) system. Confirm the
following if your unit is one of the following control
system type.
• Group control system
One remote controller controls up to 16 indoor units.
All indoor units are equally set.
• Two remote controllers control system
Two remote controllers control one indoor unit (In
case of group control system, one group of indoor
units)
The unit is individually operated.
NOTE
_:Di
• Contact your local dealer in case of changing the
combination or setting of group control and two
remote controllers control system.
• Please do not change the combination and
settings for the group operation and two remote
controllers control systems by yourself, but be
sure to ask your local dealer.
• Read the operation manual attached to the
remote controller you are using.
When using a wireless remote controller, refer to the
operation manual attached to the wireless remote
controller kit.
If your installation has a customized control
system, ask your local dealer for the operation that
corresponds to your system.
Names and functions of parts
7
2
3
D
6
d2b
13 10 11
12
9
1
Air outlet (Field supply)
2
Exhaust duct (Field supply)
3
Drain pipe
4
Refrigerant piping
5 Wiring between indoor and outdoor unit
6
Remote controller (Sold separately)
Drain discharge device (built-in)
7
Discharges indoor moisture removed during
cool-ing operation.
8 Power line
Grounding wire
9 This wire releases electricity from the indoor
unit to the ground in order to prevent electric
shock or fire.
Air filter (inside filter chamber) (Sold
10
separately)
11
Suction filter chamber (Sold separately)
12
Suction duct (Field supply)
Machine nameplate
The nameplate is imprinted with the
13
machine name and specifications.
14
Suction grille (Field supply)

3. OPERATION RANGE

If the temperature or the humidity is beyond the
following conditions, safety devices may work and
the air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
INDOOR
OUTDOOR
TEMPERA-
UNIT
TURE
D
19 to 35
B
RZMF-
w
BRV/Y16
14 to 24
B
DB: Dry bulb temperature (
WB: Wet bulb temperature (
63
OUTDOOR
TEMPERA-
HUMIDITY
TURE
80%
D 19 to 48
or below
B
°
C)
°
C)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents