Alpha-InnoTec LW 150H-A Instruction Manual

Alpha-InnoTec LW 150H-A Instruction Manual

Air / water heat pumps outside installation
Hide thumbs Also See for LW 150H-A:

Advertisement

Quick Links

Instruction Manual
Air / Water Heat Pumps
Outside installation
LW 150H-A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LW 150H-A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alpha-InnoTec LW 150H-A

  • Page 1 Instruction Manual Air / Water Heat Pumps Outside installation LW 150H-A...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY REGULATIONS In general, the following recommendations are Seite referred to this instruction manual: SAFETY REGULATIONS Safety regulations. Important! Please observe! GENERAL Please observe advice referring to function and  operating method! SCOPE OF SUPPLY Reference to instruction manual of the heat pump controller The heat pump installation must be installed TRANSPORT...
  • Page 3: General

    GENERAL SCOPE OF SUPPLY General Scope of supply Field of application Scope of supply heat pump basic device The heat pump is designed exclusively for the heating of heating circuit water and domestic hot water. Considering • Compact device with fully hermetic compressor and the application limits (see annex), the heat pump can be all relevant safety components for refrigeration circuit installed on new or existing heating systems.
  • Page 4: Transport

    TRANSPORT General Preparation Transport the device in packed condition to the final des- 1) Open the quick-release screws of the user side (side tination, on a wooden pallet, with a lift truck or a fork lift to with logo) by turning anticlockwise. avoid transportation damage.
  • Page 5: Installation

    INSTALLATION ASSEMBLY Installation Assembly / Heating water supply point When installing the device, please consider the Connection to the heating system enclosed assembly instructions and the mini- The heating system must be flushed before connecting mum distances. the heat pump to prevent contamination inside the hea- ting system affecting the function of the heat pump.
  • Page 6 ASSEMBLY Assembly / Hydraulic schematic Assembly / Heating water supply point The heat pump must be integrated in the heating circuit in accordance with the recommended hydraulic schematic - see enclosure. In accordance with the valid regulations for pressure protection, the heating circuit must be equipped with a safety valve and a pressurized expansion vessel.
  • Page 7: Hydraulic Schematic

    Luft Wasser Wärmepumpe Aussenaufstellung 7 - 19 KW 1 Heizkreis, Brauchwarmwasserbereitung V.833094 HYDRAULIC SCHEMATIC Air/Water heat pump outdoor 7 - 19 kW single source operation, domestic hot water heating Please notice: Wichtiger Hinweis: There is no complete specification of gate valves, ventilations In diesem Prinzipschema sind Absperrorgane, and safity-measures in this schematic.
  • Page 8: Power Supply

    ASSEMBLY POWER SUPPLY Installation and electric works must be carried Loosen the switching box fixings. out by competent persons and in accordance with all safety and IEE* regulations. *IEE – Institute of Electrical Engineers Please secure right rotating field of the load supply when connecting the heat pump.
  • Page 9: Terminal Connection Diagram

    ASSEMBLY POWER SUPPLY / TERMINAL CONNECTION DIAGRAM External return sensor External sensor Domestic water sensor/-thermostat (accessories) Sensor mixer 1 (accessories) Remote thermostat (accessories) Room unit (accessories) Mixer1 Closed Mixer 1 Open Heat generator 2 / collector Second heat generator 1 Domestic water circulating pump Add.
  • Page 10: Start-Up / Maintenance / Trouble-Shooting

    START-UP / MAINTENANCE / TROUBLE-SHOOTING Start up Maintenance The heat pump will be started by the heat pump controller; Clean the device with a damp cloth and a mild cleansing the commissioning is to be carried out by a competent agent.
  • Page 11: Technical Data

    TECHNICAL DATA LW 150H-A V.813051a Seite 11 TECHNICAL DATA LW 150H-A V.813051a Type of heat pump Air / Water CE-Certified Assembly outdoors Protection class IP24 Performance data Heating capacity/COP A2/W35 acc. to EN255 kW/- 9,5 / 3,3 A7/W35 acc. to EN255...
  • Page 12: Heating Capacity

    HEATING CAPACITY, COP LW 150H-A V.811027 Heizleistung (kW) Heating capacity (kW) Flow temperature 35°C Vorlauf 35°C Vorlauf 50°C Flow temperature 50°C Vorlauf 65°C Flow temperature 65°C Air temperature (°C) Lufttemperatur (°C) Leistungsaufnahme (kW) Power consumption (kW) Air temperature (°C) Lufttemperatur (°C) Air temperature (°C)
  • Page 13: Pressure Drop Curve

    PRESSURE DROP CURVE LW 150H-A V.812016 Druckverlust Heizwasser (bar) Pressure drop heating circuit water (bar) 0,30 0,28 0,26 0,24 0,22 0,20 0,18 0,16 0,25 0,001929 0,0005469 0,14 0,007716 0,0021875 0,030864 0,00875 0,123457 0,035 0,12 0,493827 0,14 0,10 0,08 0,06 0,04 1 Vorlauf 35°C...
  • Page 14: Dimensional Drawing

    DIMENSIONAL DRAWING LW 150H-A V.819189b 1394 - Heizwasser Austritt (Vorlauf) R 1 " A.G. DIN ISO 228 - Circuit chauffage départ - Heizwasser Eintritt (Rücklauf) f.e. 1 " DIN ISO 228 R 1 " A.G. DIN ISO 228 - Heating circuit water output (flow) - Circuit chauffage retour e.t.
  • Page 15: Plan Of Pedestal

    PLAN OF PEDESTAL / DISTANCES LW 150H-A V.819190 - Heizwasseranschlüsse - Wärmepumpenaußenkontur - Raccordements ean de chauffage - Contour extérieur de la pompe à chaleur - Connections heating water - Outline heat pump ca. 315 env. 315 appr. 315 > 40 über Sockel >...
  • Page 16: Minimum Distances

    MINIMUM DISTANCES LW 150H-A V.819204                           - We reserve the right to make technical changes - 830123GB/161130 ...
  • Page 17: Installation Advice

    ASSEMBLY ADVICE V.819008 830123GB/161130 - We reserve the right to make technical changes -...
  • Page 18: Noise

    Noise Noise pressure level LW 100M-A and LW 150H-A (free field) 37 dB(A) 43 dB(A) 57 dB(A) 34 dB(A) 40 dB(A) 54 dB(A) 54 dB(A) 40 dB(A) 34 dB(A) 55 dB(A) 41 dB(A) 35 dB(A) - We reserve the right to make technical changes -...
  • Page 19: Circuit Diagram

    CIRCUIT DIAGRAM PART 1 LW 150H-A V.817045a 830123GB/161130 - We reserve the right to make technical changes -...
  • Page 20 CIRCUIT DIAGRAM PART 2 LW 150H-A V.817045a - We reserve the right to make technical changes - 830123GB/161130...
  • Page 21 CIRCUIT DIAGRAM PART 3 LW 150H-A V.817045a 830123GB/161130 - We reserve the right to make technical changes -...
  • Page 22 CIRCUIT DIAGRAM PART 4 LW 150H-A V.817045a - We reserve the right to make technical changes - 830123GB/161130...
  • Page 23 CIRCUIT DIAGRAM PART 5 LW 150H-A V.817045a 830123GB/161130 - We reserve the right to make technical changes -...
  • Page 24 CIRCUIT DIAGRAM PART 6 LW 150H-A V.817045a - We reserve the right to make technical changes - 830123GB/161130...
  • Page 25: Eu-Statement Of Conformity

    EU Statement of Conformity The undersigned confirms that the following designated device(s) having the design distributed by us meet(s) the requirements of the harmonised EU directives, EU safety standards, and product-specific EU standards. This statements ceases to be valid in the event of a change to the device(s) that has not been approved by us. Designation of the device(s): EU-directives Air / water-heat pumps...
  • Page 26 NOTICE OF COMPLETION FAX TO □ > AFTER-SALES-SERVICE PARTNER I R E L A N D: +44 28 80 76 08 68 □ > AFTER-SALES-SERVICE PARTNER E N G L A N D / W A L E S: +44 845 280 33 66 __________________________________________________________________________________________________________________ NOTICE OF COMPLETION (NOC) AND REQUEST FOR START-UP BY MANUFACTURER During the start-up, the functionality and correct operation of the installation will be checked.
  • Page 27: Completion Notice

    COMPLETION NOTICE BASIC CHECK-LIST FOR COMPLETION NOTICE FOR THE HEAT PUMP SYSTEM Heat Source Air □ Conduits are connected and leak-proof o.k. □ Weather protection louvres installed o.k. □ Rotation direction of the ventilator o.k. Heat Source Brine or Water □...
  • Page 28 Alpha-InnoTec GmbH Industriestrasse 3 The future of heatpumps D-95359 Kasendorf Tel.: +49 (0)9228 9906 0 Fax.: +49 (0)9228 9906 29 e-mail: info@alpha-innotec.de www.alpha-innotec.com Certified Quality SCOTLAND ENGLAND / WALES Renewable Energy Options Ltd. In view of offering the heat pump MS Frise Ltd.